Possible Malfunctions
104523
27 / 35
EN
Malfunction
Alarm
Appliance Condition
Solution
Filling level probe
alarm
Appliance stops
Check probe connection to PCB
Check probe integrity
Replace the damaged probe
Periodic
maintenance
alarm
Appliance continues
operation
Contact the service company
(Reset the alarm by touching the
control key for 10 seconds)
Condenser high
temperature alarm
The appliance stops; the
condenser's fan remains
on in order to reduce the
condenser's temperature
Check condenser for cleanliness
and ventilation
Check fan for operation
Condenser probe
alarm
Appliance stops
Check condenser probe
connection to PCB
Replace the damaged probe
Evaporator probe
alarm
Appliance stops
Check evaporator probe
connection to PCB
Replace the damaged probe
Power supply
malfunction alarm
or no electric
supply
Appliance stops
Check electric connections and
power supply
High pressure
alarm
The appliance stops; the
condenser's fan remains
on in order to reduce the
condenser's temperature
Check condenser for cleanliness
and ventilation
Check if condenser fan rotates