Cone Table

 - Used to look up the temperature of various cone numbers.  The temperature which is displayed is for 

self-supporting cones with a heating rate of 108

°

F/hr.  To use, press Cone Table, enter the cone number you 

want to look up, press ENTER; the cone temperature will be displayed followed by CPL. 

  

Review Program

 - The information displayed when Review Program is pressed varies depending on whether you 

are using Cone Fire or Vary Fire. When Review Program is pressed, each of the steps in the current firing 
profile is displayed one after another changing every ½ second. 

 

In 

Cone Fire

 Mode - The display will show the selected firing profile in the following order: 

Cone fire speed 
preheat time (PrHt) 
cone # (ConE) 
cone temperature*  (

°

F) 

hold time (HLd) 
delay time (dELA) 
alarm setting (ALAr) 
error codes on/off (ErCd) 
LAG setting (if zone control) 

* After a firing is complete, the cone temperature (

°

F) will show the actual temperature reached 

during the firing. 

 

In 

Vary Fire

 Mode - The display will show in the following order:  

the user program # (USEr) 
the number of segments (SEG) 
1st ramp rate (rA 1) 
1st segment temperature (

°

F 1) 

1st hold time (HLd1) 
(If there is more than 1 segment, then the ramp rate, segment temperature, and hold time of 
each of the other segments will be displayed in order.) 
delay time (dELA) 
alarm setting (ALAr) 
error codes on/off (ErCd) 
LAG setting if zone control 

 
 

View Segment

  - 

only functions when a firing is in progress.  View segment is used to view the current firing 

segment or to skip from the current segment to the next firing ramp.  When View Segment is pressed during 
a firing the current segment of the firing, the travelling set-point and the circuit board temperature are 
displayed.  If it is pressed during IdLE, StOP is displayed then the current temperature. 

Skip Step (SStp) 

Skip Step (Skip Step) is  included in View Segment.  The skip step feature is only 

available in a VARY-FIRE firing profile.  It is used when enough heat work has been done at the current 
segment and you want to immediately go the next ramp rate.  To skip to the next ramp, press View Segment, 
then within ½ second, press ENTER, and ENTER a second time.  If you press View Segment and do not 
press ENTER within ½ second, the current segment (e. g., rA 1) will continue to be displayed.  Simply wait 
until the temperature is again displayed and press View Segment, then ENTER within ½ second, and 
ENTER again.  If you press View Segment, then ENTER, then decide not to skip to the next ramp stage, 
simply do not press any key; after about 10 seconds the display will return to the current temperature. 

Содержание V6-CF

Страница 1: ...Operation Manual Model V6 CF Controller BARTLETT INSTRUMENT COMPANY 1404 Avenue M Fort Madison IA 52627 319 372 8366 WWW BARTINST COM...

Страница 2: ...reset PrHt Preheat Id identification 16 S 16 segment CnoS Cone Offset CHG Change F to C ErCd Error Codes tCoS thermocouple offset bd t board temperature and LAG Lag setting 11 ZONE CONTROL 15 1 FEATU...

Страница 3: ...to the next ramp ERROR CODES Error codes may be turned on so the kiln will automatically shut down if there is an error 16 SEGMENT PROGRAMS User 5 and 6 can be combined for a 16 segment program Messa...

Страница 4: ...firing profiles OPTIONS section for setting delay start and alarm Set one of nine Other options Default reset Preheat stage time Controller ID 16 segment program Cone offset Change F to C set Error co...

Страница 5: ...ves the traveling set point according to the programmed firing rate and recalculates how much power is needed to keep the temperature at the new traveling set point This sequence continues until the f...

Страница 6: ...amming is complete press the START STOP button to begin the firing With the display flashing IdLE alternating with the current temperature you are ready to proceed to one of the programming sections T...

Страница 7: ...temperature will be flashing in the display 8 Press START STOP to begin firing NOTE With any of the CONE FIRE modes a preheat stage is available During the preheat stage the temperature is increased a...

Страница 8: ...imal point are hours to the right of decimal point are minutes NOTE For a 1 hour hold time you could also enter 60 for 60 minutes the display would show 00 60 If you type a wrong number press zero 4 t...

Страница 9: ...y flashes between F 2 the temperature which was previously programmed 14 1 5 7 5 1575 Displays the selected temperature 15 ENTER Alternately flashing HLd2 No The displays flashes between HLd2 the prev...

Страница 10: ...segment temperature and hold time of each of the other segments will be displayed in order delay time dELA alarm setting ALAr error codes on off ErCd LAG setting if zone control View Segment only fun...

Страница 11: ...ure 2 2 0 0 0200 Displays the selected temperature of 200 If you type a wrong number press zero 4 times then type the correct number 3 ENTER CPL flashes then the current temperature CPL flashes severa...

Страница 12: ...option Press Start and the controller will fire user 5 then it will fire user 6 NOTE The first segment of user 6 must be an up ramp or the segment will be skipped CnoS Cone Offset Used to raise or low...

Страница 13: ...splayed press ENTER and the current offset for the thermocouple will be displayed Press ENTER when the correct offset is displayed The following apply to T C offsets The final temperature is affected...

Страница 14: ...des are off The current temperature then flashes in the display bd t circuit board temperature Press enter when bd t is displayed and the circuit board temperature will be displayed It is used for dia...

Страница 15: ...he sections but it will increase the firing time rSEt will set the lag to 13 Therefore anytime a section is more than 13 degrees behind the traveling set point the controller will wait for the lagging...

Страница 16: ...o 13 and error codes ErCd set to on PREHEAT PrHt CONE OFFSET CnoS CHANGE F C CHG all work as described in the OPTIONS SECTION under Programming ERRORS ON OFF ErCd also referred to as error checking wo...

Страница 17: ...ption Quick View Err0 Software Error Recheck the selected program and reprogram if necessary If error persists return controller for service Err1 The temperature is increasing less than 12 degrees per...

Страница 18: ...e fire mode only Temp decreasing during last ramp segment ErrP Continuous ErrP in display Indicates a long term power outage The kiln has been shut down Press 1 to clear the display ErrP ErrP and the...

Страница 19: ...necting the thermocouple connect the RED wire to the connector with RED dot and connect the YELLOW wire to the connector with the YELLOW dot On all thermocouples the RED wire is always negative the ye...

Страница 20: ...C 1 YELLOW OUTPUT 3 BOTTOM RED AC 1 T C2 YELLOW RED A B T C 3 YELLOW RS 485 RED OUTPUT 1 TOP 24V center tap transformer Line Voltage input Relay Top Relay Middle Relay Bottom CENTER TAP AC 2 Connect T...

Отзывы: