ZONE CONTROL 

1.  FEATURES AND INHANCEMENTS  

• 

3 separately controlled zones ( 3 t/c inputs, 3 outputs ) 

• 

Adjustable offsets for each thermocouple (t/c) 

• 

Continues to fire with 1 or 2 failed thermocouples (t/c’s) 

• 

Suspend ramping when any zone lags the set-point 

• 

Reset function which  zeros the t/c offsets, turns the  errors on, and sets the lag to 13 degrees 

• 

Decimal points in the display can be used as pilot lights 

Press the “8” key during a firing and the 1000’s decimal point will light when the top elements are on, 100’s 
decimal point when middle elements are on, and 10’s decimal point when the bottom elements are on. 

2.  GENERAL DESCRIPTION 

The V6-CF advanced  3-zone control system is programmed the same as the single zone control but it has new  
features to ensure even firing from the top to the bottom of the kiln.  A 3-zone control has 3 temperature sensor inputs 
(thermocouples) and 3 independent outputs so the kiln can have 3 separately controlled sections (zones).   The 
controller senses the temperature in each section of the kiln, compares the temperature to the desired temperature  
(traveling set-point) and adjusts the power going to each section separately giving each just the right amount of power 
to keep the temperature at the correct setting.    The single zone controller only measures the temperature at the center 
of the kiln and gives all sections the same amount of power. 

3.  ADJUSTABLE LAG 

For tighter control from one section to the next, the controller has a  programmable “lag” feature so the user can set 
how much the temperature in any zone can lag behind the traveling set-point.  The maximum lag setting is 99, the 
default setting is 13.  The controller senses when any section is lagging behind the traveling set-point and keeps the 
controller from increasing the traveling-set point until the lagging section catches up.  Ramping of the traveling set-
point is only suspended when a section is behind by more than the programmed “lag”.   A smaller “lag” will result in 
tighter control between the sections but it will increase the firing time.  “rSEt” will set the “lag” to 13.  Therefore, 
anytime a section is more than 13 degrees behind the traveling set-point the controller will wait for the lagging section 
to catch up before increasing the traveling set-point.  Turning error codes (ErCd) off will also turn off the lag feature. 

4.  THERMOCOUPLE OFFSETS ( see T/C offsets and Cone offsets in the OPTIONS 
SECTION for more information) 

Normal variation in thermocouples  (t/c) can cause a section to fire too hot or too cool.  The zone control has an offset 
feature to adjust the reading of each thermocouple to compensate for any error.  For example, if shelf cones indicate 
that the bottom section is under firing, it means that the controller thinks the bottom section actually reached the 
ending temperature when it really was below the ending temperature.  To correct this problem, a negative 
thermocouple offset is required.  This offset will be subtracted from the actual reading and will lower the temperature 
reading in that section.  A negative offset will cause a  section to fire to a higher temperature increasing the heat-work  
for that section.  A positive offset will cause a  section to fire to a lower  temperature decreasing the heat-work  for 
that section. “rSEt” in Other menu will return all the t/c offsets to 0. 

5.  THREE THERMOCOUPLES   

Besides better measuring of the temperature, the zone control also offers security through its three thermocouples.  
With a single zone controller, a firing will be stopped if the thermocouple (t/c) fails.  The zone control with 3 t/c’s, 
will continue to fire if one or two of its thermocouples fail during a firing.  If the top or bottom thermocouple fails 
that section will be controlled by the middle t/c.  If the middle thermocouple fails the middle section will be controlled 
by the top t/c.   If at “IdLE” and a t/c fails, the display will alternate between FAIL and the number of the failed t/c 
(1,2,3).  The temperature of each zone can be viewed. The temperature will alternately flash with the currently 
selected zone.  To select zone 1, press the “1” key and tC 1 will alternate with the current zone 1 temperature.  For 
zone 2 press the “2” key, for zone 3 press the “3” key. 

Содержание V6-CF

Страница 1: ...Operation Manual Model V6 CF Controller BARTLETT INSTRUMENT COMPANY 1404 Avenue M Fort Madison IA 52627 319 372 8366 WWW BARTINST COM...

Страница 2: ...reset PrHt Preheat Id identification 16 S 16 segment CnoS Cone Offset CHG Change F to C ErCd Error Codes tCoS thermocouple offset bd t board temperature and LAG Lag setting 11 ZONE CONTROL 15 1 FEATU...

Страница 3: ...to the next ramp ERROR CODES Error codes may be turned on so the kiln will automatically shut down if there is an error 16 SEGMENT PROGRAMS User 5 and 6 can be combined for a 16 segment program Messa...

Страница 4: ...firing profiles OPTIONS section for setting delay start and alarm Set one of nine Other options Default reset Preheat stage time Controller ID 16 segment program Cone offset Change F to C set Error co...

Страница 5: ...ves the traveling set point according to the programmed firing rate and recalculates how much power is needed to keep the temperature at the new traveling set point This sequence continues until the f...

Страница 6: ...amming is complete press the START STOP button to begin the firing With the display flashing IdLE alternating with the current temperature you are ready to proceed to one of the programming sections T...

Страница 7: ...temperature will be flashing in the display 8 Press START STOP to begin firing NOTE With any of the CONE FIRE modes a preheat stage is available During the preheat stage the temperature is increased a...

Страница 8: ...imal point are hours to the right of decimal point are minutes NOTE For a 1 hour hold time you could also enter 60 for 60 minutes the display would show 00 60 If you type a wrong number press zero 4 t...

Страница 9: ...y flashes between F 2 the temperature which was previously programmed 14 1 5 7 5 1575 Displays the selected temperature 15 ENTER Alternately flashing HLd2 No The displays flashes between HLd2 the prev...

Страница 10: ...segment temperature and hold time of each of the other segments will be displayed in order delay time dELA alarm setting ALAr error codes on off ErCd LAG setting if zone control View Segment only fun...

Страница 11: ...ure 2 2 0 0 0200 Displays the selected temperature of 200 If you type a wrong number press zero 4 times then type the correct number 3 ENTER CPL flashes then the current temperature CPL flashes severa...

Страница 12: ...option Press Start and the controller will fire user 5 then it will fire user 6 NOTE The first segment of user 6 must be an up ramp or the segment will be skipped CnoS Cone Offset Used to raise or low...

Страница 13: ...splayed press ENTER and the current offset for the thermocouple will be displayed Press ENTER when the correct offset is displayed The following apply to T C offsets The final temperature is affected...

Страница 14: ...des are off The current temperature then flashes in the display bd t circuit board temperature Press enter when bd t is displayed and the circuit board temperature will be displayed It is used for dia...

Страница 15: ...he sections but it will increase the firing time rSEt will set the lag to 13 Therefore anytime a section is more than 13 degrees behind the traveling set point the controller will wait for the lagging...

Страница 16: ...o 13 and error codes ErCd set to on PREHEAT PrHt CONE OFFSET CnoS CHANGE F C CHG all work as described in the OPTIONS SECTION under Programming ERRORS ON OFF ErCd also referred to as error checking wo...

Страница 17: ...ption Quick View Err0 Software Error Recheck the selected program and reprogram if necessary If error persists return controller for service Err1 The temperature is increasing less than 12 degrees per...

Страница 18: ...e fire mode only Temp decreasing during last ramp segment ErrP Continuous ErrP in display Indicates a long term power outage The kiln has been shut down Press 1 to clear the display ErrP ErrP and the...

Страница 19: ...necting the thermocouple connect the RED wire to the connector with RED dot and connect the YELLOW wire to the connector with the YELLOW dot On all thermocouples the RED wire is always negative the ye...

Страница 20: ...C 1 YELLOW OUTPUT 3 BOTTOM RED AC 1 T C2 YELLOW RED A B T C 3 YELLOW RS 485 RED OUTPUT 1 TOP 24V center tap transformer Line Voltage input Relay Top Relay Middle Relay Bottom CENTER TAP AC 2 Connect T...

Отзывы: