background image

WELCOME !! 

Thank you for purchasing a Model V6-CF temperature controller.  The Model V6-CF is an enhanced version of  previous 
controllers which have been offered.  We hope this manual helps you learn to use your controller quickly and efficiently.  
Additional information can be found on the internet at 

www.bartinst.com 

 

FEATURES 

∗ 

Firing methods and features which make firing easier:  

• 

CONE FIRE METHOD

 -  Used  to fire to a specific cone number using one of four speeds, “Slow Bisque”, “Fast 

Bisque”, “Slow Glaze”, or “Fast Glaze”. 

• 

VARY-FIRE PROGRAMMER

 - Program up to 6 separate firing profiles for repeated use.  Each profile may have 

up to 8 segments with separate heating or cooling rates, temperature set-points, and hold times. 

• 

DELAY START

 - Delay the start of your firing up to 99 hours and 99 minutes. 

• 

PREHEAT

 - Used with CONE FIRE mode to hold at a temperature of 200 

°

F for a specified time then go 

automatically into the cone fire program.  This can be used for drying ware.   

• 

ALARM

 - User set audible temperature alarm. 

∗ 

Advanced features: 

• 

CONE OFFSET

 - Used to raise or lower the final temperature of any cone to fine tune the controller to your kiln. 

• 

SKIP STEP 

-Skip from the present segment to the next ramp. 

• 

ERROR

 

CODES

 - Error codes may be turned on so the kiln will automatically shut down if there is an error. 

• 

16 SEGMENT PROGRAMS 

– User 5 and 6 can be combined for a 16 segment program. 

∗ 

Messages and information: 

• 

REVIEW PROGRAM - 

Review your firing profile any time before or during the firing. 

• 

VIEW SEGMENT

 - View the current segment, set-point, board temperature, or skip to the next segment. 

• 

CONE TABLE - 

Easily look up temperature and cone number equivalents.   

• 

Choose between 

FARENHEIT

 or 

CELCIUS

 temperature scales.

 

*   

Communicates with personal computer equipped with 

KISS

 software. 

 

Precautions 

 

The controller is used to control temperature, it is not a safety device. 
 
Do not operate the controller in temperatures above 125 

°

F.   

 
Never leave your kiln unattended at the end of a firing. 
 
The controller contains electronic components which are sensitive to static electricity.  Before handling the controller dissipate 
any static charge you may have by touching metal or a screw on the controller panel, the electrical box, the kiln lid, or some 
other grounded object.   
 
Always check the position of the thermocouple probe before starting a firing.  The current temperature displayed on the 
controller is measured at the end of the thermocouple which must be in the firing chamber 
 
Always review the current program before firing to ensure the correct profile is programmed.

 

Содержание V6-CF

Страница 1: ...Operation Manual Model V6 CF Controller BARTLETT INSTRUMENT COMPANY 1404 Avenue M Fort Madison IA 52627 319 372 8366 WWW BARTINST COM...

Страница 2: ...reset PrHt Preheat Id identification 16 S 16 segment CnoS Cone Offset CHG Change F to C ErCd Error Codes tCoS thermocouple offset bd t board temperature and LAG Lag setting 11 ZONE CONTROL 15 1 FEATU...

Страница 3: ...to the next ramp ERROR CODES Error codes may be turned on so the kiln will automatically shut down if there is an error 16 SEGMENT PROGRAMS User 5 and 6 can be combined for a 16 segment program Messa...

Страница 4: ...firing profiles OPTIONS section for setting delay start and alarm Set one of nine Other options Default reset Preheat stage time Controller ID 16 segment program Cone offset Change F to C set Error co...

Страница 5: ...ves the traveling set point according to the programmed firing rate and recalculates how much power is needed to keep the temperature at the new traveling set point This sequence continues until the f...

Страница 6: ...amming is complete press the START STOP button to begin the firing With the display flashing IdLE alternating with the current temperature you are ready to proceed to one of the programming sections T...

Страница 7: ...temperature will be flashing in the display 8 Press START STOP to begin firing NOTE With any of the CONE FIRE modes a preheat stage is available During the preheat stage the temperature is increased a...

Страница 8: ...imal point are hours to the right of decimal point are minutes NOTE For a 1 hour hold time you could also enter 60 for 60 minutes the display would show 00 60 If you type a wrong number press zero 4 t...

Страница 9: ...y flashes between F 2 the temperature which was previously programmed 14 1 5 7 5 1575 Displays the selected temperature 15 ENTER Alternately flashing HLd2 No The displays flashes between HLd2 the prev...

Страница 10: ...segment temperature and hold time of each of the other segments will be displayed in order delay time dELA alarm setting ALAr error codes on off ErCd LAG setting if zone control View Segment only fun...

Страница 11: ...ure 2 2 0 0 0200 Displays the selected temperature of 200 If you type a wrong number press zero 4 times then type the correct number 3 ENTER CPL flashes then the current temperature CPL flashes severa...

Страница 12: ...option Press Start and the controller will fire user 5 then it will fire user 6 NOTE The first segment of user 6 must be an up ramp or the segment will be skipped CnoS Cone Offset Used to raise or low...

Страница 13: ...splayed press ENTER and the current offset for the thermocouple will be displayed Press ENTER when the correct offset is displayed The following apply to T C offsets The final temperature is affected...

Страница 14: ...des are off The current temperature then flashes in the display bd t circuit board temperature Press enter when bd t is displayed and the circuit board temperature will be displayed It is used for dia...

Страница 15: ...he sections but it will increase the firing time rSEt will set the lag to 13 Therefore anytime a section is more than 13 degrees behind the traveling set point the controller will wait for the lagging...

Страница 16: ...o 13 and error codes ErCd set to on PREHEAT PrHt CONE OFFSET CnoS CHANGE F C CHG all work as described in the OPTIONS SECTION under Programming ERRORS ON OFF ErCd also referred to as error checking wo...

Страница 17: ...ption Quick View Err0 Software Error Recheck the selected program and reprogram if necessary If error persists return controller for service Err1 The temperature is increasing less than 12 degrees per...

Страница 18: ...e fire mode only Temp decreasing during last ramp segment ErrP Continuous ErrP in display Indicates a long term power outage The kiln has been shut down Press 1 to clear the display ErrP ErrP and the...

Страница 19: ...necting the thermocouple connect the RED wire to the connector with RED dot and connect the YELLOW wire to the connector with the YELLOW dot On all thermocouples the RED wire is always negative the ye...

Страница 20: ...C 1 YELLOW OUTPUT 3 BOTTOM RED AC 1 T C2 YELLOW RED A B T C 3 YELLOW RS 485 RED OUTPUT 1 TOP 24V center tap transformer Line Voltage input Relay Top Relay Middle Relay Bottom CENTER TAP AC 2 Connect T...

Отзывы: