6.11.8
Data cable and power supply (Universal supply module to PC/Host)
Data line:
BARTEC recommends the use of the following cables:
Commercially available shielded data cable to avoid external interference into the
data cable e.g. min. CAT5 cable or other shielded cable to avoid external
interference into the data cable
The following core cross-sections and number of cores:
Interface
Recommended
wire cross section
Number of conductor
RS232
0,2 mm
2
to 2,5 mm
2
24 – 14 AWG
5
RS422
4
RS485
4
USB-SPP
4
This connection to the host PC is done by the customer.
No cables manufactured by BARTEC are used.
The connection is made by customer-specific cable connections.
Note for use of USB connection cables
The color assignment of the USB cables is not standardized.
Which colour is used for USB wires D+ and D- depends on the USB cable manufacturer.
Tip: Before wiring, measure the cable to know which wires are D+ and D-.
Connector Type A
Socket connector Type A
Pin
Color
Signal
1
Red
V
CC
5 V
DC
2
Grey
Daten (D-)
3
Green
Daten (D+)
4
Black
Ground (GND)