BCS3600
ex
series
Hand-held scanner and accessories
Configuration
Subject to technical changes.
April 2022 / Revision C
135/164
9.6
Programming the interface parameters
9.6.1
Programming BCS3608
ex
with universal supply module – corded
Pos.
Description
1
Power supply
this cable has to be provided by the customer
2
Host-PC
3
Data cable Host-PC – Universal supply module
this cable has to be provided by
the customer
4
Universal supply module corded
Type: B7-A2Z0-0042/**** (Zone 2/22 or Division 2)
Type: 17-A1Z0-0018/**** (Zone 1/21)
5
Connecting cable BCS3608
ex
-NI / BCS3608
ex
-IS
6
Corded hand-held scanner BCS3608
ex
-NI / BCS3608
ex
-IS
Type: B7-A2S4-1HP0/**** (Zone 2/22)
Type: B7-A2S4-1ER0/**** (Zone 2/22)
Type: 17-A1S4-1HP0/**** (Zone 1/21)
The corded universal supply module transmits the data of the serial interface of the hand-
held scanner transparently (1 to 1) and therefore changes of the settings on the module are
not necessary.
To create a connection to a PC, the interface parameters on the hand-held scanner and the
PC/host must be identical.
Adjustment on the hand-held scanner:
The interface parameters of the hand-held scanner can be adjusted using programming
codes in the Zebra product manual (chapter 7 or 9) or when using the Zebra 123 Scan
Utility (only when using a programming cable).
Adjustment on the universal supply module - corded:
No adjustment necessary, because the universal supply module transparently transmits the
data from the hand-held scanner to the PC/host.
Adjustment on PC/host:
The interface parameters of the PC/host can be adjusted via the settings e.g. in the device
manager, terminal program or application software.