Commissioning
BCS3600
ex
series
Hand-held scanner and accessories
46/164
Subject to technical changes.
April 2022 / Revision C
6.4
Bluetooth Hand-held scanner BCS3678
ex
-NI / BCS3678
ex
-IS
6.4.1
Insert/change battery
DANGER
Mixing up the batteries!
Only use batteries that have been specified by BARTEC.
Utilisez uniquement la batterie qui a été spécifiée par BARTEC.
Spark formation when changing the battery!
Only insert or remove the battery outside the potentially explosive atmosphere.
Insérez ou retirez la batterie uniquement en dehors de tout risque d'explosion.
Spark formation when charging the battery!
Only charge the battery outside the potentially explosive atmosphere.
Chargez la batterie uniquement en dehors des zones à risque d'explosion
Only the following batteries are approved:
Zone / Div
Battery type
Zone 0/20, Div 1
17-A1Z0-0012
Zone 2/20; Div 2
B7-A2Z0-0036
Содержание BCS3600ex Series
Страница 1: ...Hand held scanner BCS3600ex series User Manual...
Страница 2: ......
Страница 4: ......
Страница 172: ...Notes BCS3600ex series Hand held scanner and accessories 164 164 Subject to technical changes April 2022 Revision C...
Страница 173: ......