Commissioning
BCS3600
ex
series
Hand-held scanner and accessories
58/164
Subject to technical changes.
April 2022 / Revision C
6.7.1
HMI limiting cable USB
Specified cables
Version
Length
BARTEC Order-No.
HMI limiting cable
USB
1,9 m
B7-A2Z0-0041
HMI limiting cable
USB
4,5 m
B7-A2Z0-0054
The HMI limiting cable USB can be connected directly to the HMI or the USB connection
(BARTEC Order no. B7-A2Z0-0074) can be used optional.
RJ-50
(10 Pin)
Connector
HMI limiting cable
Version: USB
USB connection
(optional)
Description
of the cores
Red = V+
Pin 1
Black= GND
Pin 10
Green = D-
White = D+
Grey = Shield
Internal power supply at the HMI USB module must be at least 5V DC / 500 mA.
6.7.2
HMI limiting cable RS232
Specified cables
Version
Length
BARTEC Order-No.
HMI limiting cable
RS232
1,9 m
B7-A2Z0-0040
HMI limiting cable
RS232
4,5 m
B7-A2Z0-0050
RJ-50
(10 Pin)
Connector
HMI limiting cable
Version: RS232
Description
of the cores
Yellow = V+ (12V DC)
Pin 1
Black = GND
Pin 10
White = TxD/RxD
Green = RxD/TxD
Grey = Shield
An external power supply is necessary to supply the hand-held scanner.
The RS232 interface itself is not able to provide the necessary power supply.
The external power supply has to be at least 5V DC / 500 mA to operate the hand-held
scanner at a RS232 interface.