6.7.3
Terminal assignment Supply module Ex i
Terminal assignment for the installation of power supply cables and connection cables on
the host PC side.
The following interfaces are supported: USB-SPP und RS232
ATTENTION
The supply module can be destroyed if the terminals are incorrectly assigned!
Note the correct assignment of the terminals.
Terminal block
Possible marking
(depending on selected version and interface)
Terminal
Marking
Input voltage range
USB-SPP
RS232
X1
L
L = 100 V
AC
bis 240 V
AC
±10% / 50/60 Hz
X2
N
N = Neutral conductor
X3 +
24
V
DC
±10%
X4 –
GND
Supported data interface
USB-SPP
RS232
X5
–
TxD
X6
Placing the shield
X7
GND
GND
X8
Data+
(D+)
-
X9
Data-
(D-)
-
X10
5 V
5 V
The wire mesh of the data cable must be inserted into the shield clamp and the mesh
must also be connected to terminal for the shield.