Supply module Ex i
The supply module Ex i has a connection compartment on the output side for mains
connection in Ex e and data cable in Ex i version.
The USM enables a scanner to be operated directly in the Ex-area and the data to be
transferred to another Ex i PC/Host System in the Ex area.
Important is:
For the mains connection an Ex e compliant cable installation and its connection.
For the data line in Ex i version, the Ex i values of both systems must be compatible
to each other. The cable routing and connection must conform to the applicable
installation guidelines for Ex i.
The Ex-relevant values of the supply module Ex i are listed in the certificate and in the
chapter: Ex-relevant values.
Supply module Ex i und scanners
Type
Supply module Ex i corded
for hand-held scanner BCS3608
ex
-IS
17-A1Z0-0025
Supply module Ex i Bluetooth
for hand-held scanner BCS3678
ex
-IS
17-A1Z0-0028