Technical data
BCS3600
ex
series
Hand-held scanner and accessories
20/68
Subject to technical changes.
March 2021 / Revision B
4.1.5
Supply module Ex i for BCS3608
ex
-IS (Typ: 17-A1Z0-0025/****)
ATEX Zone 1 / 21
Labelling
II 2(1)G Ex eb ib ma [ia Ga] IIC T4 Gb
II 2(1)D Ex tb ib [ia Da] IIIC T80°C Db
Test certificate
EPS 18 ATEX 1 013 X
Standards
see chapter: EU Declaration of Conformity
IECEx Zone 1 / 21
Labelling
Ex eb ib ma [ia Ga] IIC T4 Gb
Ex tb ib [ia Da] IIIC T80°C Db
Test certificate
IECEx EPS 18.0009X
Standards
see chapter: EU Declaration of Conformity
4.1.6
Supply module Ex i for BCS3678
ex
-IS (Type: 17-A1Z0-0028/****)
ATEX Zone 1 / 21
Labelling
II 2G Ex eb ib ma IIC T4 Gb
II 2D Ex tb ib IIIC T80°C Db
Test certificate
EPS 18 ATEX 1 013 X
Standards
see chapter: EU Declaration of Conformity
IECEx Zone 1 / 21
Labelling
Ex eb ib ma IIC T4 Gb
Ex tb ib IIIC T80°C Db
Test certificate
IECEx EPS 18.0009X
Standards
see chapter: EU Declaration of Conformity
4.1.7
Special conditions for Explosion protection IS
X - labelling (special conditions of use for secure operation within the potentially
explosive atmosphere)
The ambient temperature range is -20 °C
≤
Ta
≤
+50 °C.*
The device must be protected from impact with high impact energy, from intense UV-
irradiation, and strongly charge generating processes.
It is not allowed to use connectors inside the potentially explosive atmosphere.*
*See individual chapters on the items in this User Manual.