Commissioning
BCS3600
ex
series
Hand-held scanner and accessories
54/68
Subject to technical changes.
March 2021 / Revision B
6.7.5
Communication via supply modules to host or PC
Only one communication direction is supported by the supply modules:
Unidirektional (Uni):
Only data from the hand-held scanner over a supply module can be sent to a host/PC.
Sending data from the host/PC to the hand-held scanner (remote control) is not
supported.
6.7.6
Range/maximum cable length of the connected cables from the supply modules to host or PC
Supported
interface
Universal supply
module
Supply module
Ex i
Range
USB-SPP
Yes
Yes
5 m
16 ft.
RS232
Yes
Yes
15 m
50 ft.
RS422
Yes
-
1000 m
3280 ft.
RS485
Yes
-
1200 m
3937 ft.
6.7.7
Ferrite core for data line (only when using the USB-SPP interface)
A plastic bag with a ferrite core is supplied with each supply module.
The ferrite core is only needed when using the USB-SPP interface.
It is used for shielding and avoiding external interferences on the data line.
The ferrite core must be mounted as follows:
Strip the insulation of data cable
Push the ferrite core over the data cable.
Place the data cable with bare shield in the shield terminal (on the board).
Connect the data line to the terminal.
Ferrite core for shielding
external interference signals
Installation in a supply module