![Barko 830B Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/barko/830b/830b_service-manual_3876337055.webp)
20-13
®
PILOT DRIVE MANIFOLD
GB PORT
BRAKE PRESSURE
REDUCING VALVE
(PR1)
BRAKE SEQUENCE
VALVE (SQ)
BRAKE NEEDLE
VALVE (NV)
PILOT PRESSURE
REDUCING VALVE
(PR2)
PRGP PORT
Fig-1
1 PRESSURE SETTING
(refer to
Fig-1
for the following procedures)
Ÿ
Brake Sequence Valve-
Is somewhat similar to a relief valve except that, after the set pressure has
been reached, the sequence valve diverts the fluid to the brakes.
2800 PSI
is the factory
recommended pressure value.
Ÿ
Brake Pressure Reducing Valve-
Ensures there is sufficient pressure to stop the machine on
demand.
3000 PSI
is the factory recommended pressure value.
Ÿ
Pilot Pressure Reducing Valve-
Ensures there is enough pilot pressure to engage the front and
rear differentials.
625 PSI
is the factory recommended pressure value. Setting above this value can
cause damage to the differentials.
The Pilot Drive Manifold diverts hydraulic fluid/presures
to various functions on this machine.
Proper settings of
this manifold are vital to machine performance.
BARKO Machine Applications for PILOT DRIVE
MANIFOLD:
BARKO P/N
Barko Application
Ÿ
563-01196
830B, 930B, 937B
05/30/2019
Updated
SERVICE
Содержание 830B
Страница 4: ...THIS PAGE INTENTIONALLY BLANK SUPERIOR WI USA www barko com...
Страница 42: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 44: ...20 2 SUPERIOR WI USA www barko com Part No 605 01591 HYD AY WFB 830B 05 30 2019 Updated SERVICE...
Страница 45: ...20 3 SUPERIOR WI USA www barko com Part No 605 01591 HYD AY WFB 830B 05 30 2019 Updated SERVICE...
Страница 48: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 50: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 54: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 60: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 70: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 94: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 102: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 104: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 113: ...26 11 SERVICE HEATER AC UNIT WFB continued 1 2 2 Fig 3 548 04558 Schematic Fig 3 05 31 2019 Updated SERVICE...
Страница 114: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 118: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 124: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 133: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 134: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 138: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 172: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 181: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 182: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 184: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 194: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 207: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 208: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 210: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 215: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 216: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 217: ...THIS PAGE LEFT INTENTIONALLY BLANK...