7. Service Mode
Overview of the CLO menu
Following ’Adjustable’ parameters are available in the CLO menu:
•
Tracking Interval: this parameter will determine the time between each Light Measurement.
Following Tracking Intervals are available:
- 8s
- 16s
- 32s
- 64s
- 128s
•
Target Light Value: this parameter will set the desired Constant Light Output Value.
Following parameters can be consulted to start up or maintain a setup with projectors running in CLO mode:
•
light value: this parameter will display the current Light Output Value measured by the Light Sensor.
•
tracking in range: CLO is running in optimal conditions when this parameter indicates [YES].
•
measuring in range: CLO is running in optimal conditions when this parameter indicates [YES].
How to use the CLO menu?
1. Push the cursor key
↑
or
↓
to highlight
CLO.
DIMMING
LAMP DIMMING
MOTORIZED DIMMING
CLO
Select with
↑
or
↓
then <ENTER>
<EXIT> to return
Menu 7-29
2. Press
ENTER
to select.
The
CLO
menu will be displayed.
3. Push the cursor key
↑
or
↓
to highlight Target Light Value and press
ENTER
to select.
CONSTANT LIGHT OUTPUT
TRACKING INTERVAL [OFF]
TARGET LIGHT VALUE 8000
_______________________
STATUS
light value 931
tracking in range [YES]
meas.
in range [YES]
Select with
↑
or
↓
then <ENTER>
<EXIT> to return
Menu 7-30
4. Use the cursor keys
←
or
→
in combination with the numeric keys to enter the Target Light Value, e.g. 8000, and press
ENTER
to confirm.
5. Push the cursor key
↑
or
↓
to highlight Tracking Interval and press
ENTER
to select.
CONSTANT LIGHT OUTPUT
TRACKING INTERVAL [OFF]
TARGET LIGHT VALUE 8000
_______________________
STATUS
light value 931
tracking in range [YES]
meas.
in range [YES]
Select with
↑
or
↓
then <ENTER>
<EXIT> to return
Menu 7-31
192
R5976707 REALITY SIM 6 ULTRA II 01/02/2005
Содержание BarcoReality SIM 6 Ultra II
Страница 1: ...Reality SIM 6 Ultra II Owner s Manual R9040152 R5976707 01 01 02 2005 ...
Страница 4: ......
Страница 12: ...1 Packaging and Dimensions 8 R5976707 REALITY SIM 6 ULTRA II 01 02 2005 ...
Страница 20: ...2 Installation Guidelines 16 R5976707 REALITY SIM 6 ULTRA II 01 02 2005 ...
Страница 32: ...3 Connections 28 R5976707 REALITY SIM 6 ULTRA II 01 02 2005 ...
Страница 218: ...10 Cleaning the Dustfilter 214 R5976707 REALITY SIM 6 ULTRA II 01 02 2005 ...
Страница 222: ...Index 218 R5976707 REALITY SIM 6 ULTRA II 01 02 2005 ...