background image

SureCross™ DX80 Quick Start Guide

P/N 128185 Rev A

Banner Engineering Corp. • Minneapolis, MN U.S.A.

www.bannerengineering.com  •  Tel: 763.544.3164

22

FCC Certifi cation

The DX80 Module complies with Part 15 of the FCC rules and regulations.

FCC ID: TGUDX80

 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device 

may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause 
undesired operation.

FCC Notices

IMPORTANT: The DX80 Modules have been certi

fi

 ed by the FCC for use with other products without any further certi

fi

 cation (as per FCC 

section 2.1091). Changes or modi

fi

 cations not expressly approved by the manufacturer could void the user’s authority to operate the 

equipment.
IMPORTANT: The DX80 Modules have been certi

fi

 ed for 

fi

 xed base station and mobile applications. If modules will be used for portable 

applications, the device must undergo SAR testing.
IMPORTANT: If integrated into another product, the FCC ID label must be visible through a window on the 

fi

 nal device or it must be visible 

when an access panel, door, or cover is easily removed. If not, a second label must be placed on the outside of the 

fi

 nal device that contains 

the following text: Contains FCC ID: TGUDX80.

Note

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These 
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, 
and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to 
radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause 
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to 
try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna,
Increase the separation between the equipment and receiving module,
Connect the equipment into an outlet on a circuit different from that to which the receiving module is connected, and/or
Consult the dealer or an experienced radio/TV technician for help.

Antenna Warning WARNING: This device has been tested with Reverse Polarity SMA connectors with the antennas listed in Table 1 
Appendix A. When integrated into OEM products, 

fi

 xed antennas require installation preventing end-users from replacing them with non-

approved antennas. Antennas not listed in the tables must be tested to comply with FCC Section 15.203 (unique antenna connectors) and 
Section 15.247 (emissions).

FCC-Approved Antennas

WARNING: This equipment is approved only for mobile and base station transmitting devices. Antenna(s) used for this transmitter must be 
installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any 
other antenna or transmitter.
DX80 Module may be used only with Approved Antennas that have been tested with this module.




Part Number

Antenna Type

Maximum Gain

  —

Integral antenna

Unity gain

BWA-9O1-x

Omni, 1/4 wave dipole

2 dBi

BWA-9O2-C

Omni, 1/2 wave dipole, Swivel

2 dBi

BWA-9O6-A

Omni Wideband, Fiberglass Radome

8.2 dBi

BWA-9O5-B

Omni Base Whip

7.2 dBi

BWA-9Y10-A

Yagi

10 dBi

Table 1. Type certified Antenna

Agency Certification - 900 MHz

Содержание SureCross DX80

Страница 1: ...e transmission path The Gateway receives a transmission from one Node and forwards it to another Node positioned to avoid the obstacle Host connected systems can contain up to 15 nodes within a single...

Страница 2: ...s chosen Push Button 2 Double click to select a menu and to enter manual scrolling mode Double click to move up one level at a time LED 1 and 2 Provide real time feedback to the user regarding RF link...

Страница 3: ...strial DX80 housing meets IEC IP67 standards Mounting Hole 10 M5 Clearance Mounting Holes accept metric M5 or UNC UNF 10 hardware DIN rail mount adapter bracket available Wiring Terminal Strip Wiring...

Страница 4: ...D SAVESNEW VALUES CUR XX Single click Button 2 Single click Button 2 ADJUSTROTARY SWITCHES TOSET SLAVEID SAVESNEW VALUES NID SLID BAUD PRTY Network ID Slave ID Baud Rate Parity Single click B1 NEW XX...

Страница 5: ...ouble click Btn 2 NEW XX Single click Button 2 Single click Button 2 SAVESNEW VALUES NADR Node Address NOD XX EC XX IGNORE ERROR Single click Button 1 LCD will display NO ERR if no error is detected S...

Страница 6: ...hexidecimal 0 F On the Gateway set the Right Rotary Switch to 0 A Device Address of 0 on the Gateway will display settings for the Gateway itself To view settings for another device on the network adj...

Страница 7: ...e is Gateway Device Address 0 Indicates the current status of the I O The display cycles through each I O point of the device then returns to RUN Apply power This reading occurs only when power is app...

Страница 8: ...LED 2 flashes Red When communication is established the Node s LED 1 flashes Green Status LED 1 LED 2 Power ON Green ON System Error Red Flash Red Flash Modbus Communication Active Yellow Flash Modbus...

Страница 9: ...ble install all devices in positions that optimize the percentage of YELLOW and GREEN data packets received Examine reception readings M R Y G of the Gateway at various locations Note that the numbers...

Страница 10: ...le surfaces Avoid mounting the units on flat or concave surfaces especially if the display will be pointing up Reduce Chemical Exposure Before installing the DX80 units in a chemically harsh environme...

Страница 11: ...loosely and Pushed against the flanged cover When removing or closing the rotary switch access cover manually twist the cover into position Do not allow cross threading between the cover and the DX80...

Страница 12: ...ically for optimal RF communication If necessary consider changing the height of the DX80 position to improve reception levels A wireless network can be hindered by radio interference and obstructions...

Страница 13: ...e o ring when it is damaged discolored or showing signs of wear The o ring should be Seated firmly against the threads without stretching to fit or without bulging loosely and Pushed against the flang...

Страница 14: ...of the battery holder mounted within the case After replacing the battery allow up to 60 seconds for the device to power up When removing the battery press the battery towards the negative terminal to...

Страница 15: ...shown below The following procedure is necessary to change the Gateway Slave ID Baud Rate and Parity Parameter Description Slave ID Default 1 Defines the slave number 01 99 for the serial Modbus RTU p...

Страница 16: ...19200 Single click Gateway push button 2 to save the new setting Single click Gateway push button 1 to move to the next field the PARITY field Single click Gateway push button 2 to display the current...

Страница 17: ...annerengineering com Tel 763 544 3164 SureCross DX80 Quick Start Guide 17 DX80 Gateway and Node Dimensions 65 0 mm 2 56 65 0 mm 2 56 80 3 mm 3 16 80 8 mm 3 18 60 mm 2 36 120 mm 4 72 127 mm 5 19 mm 0 7...

Страница 18: ...f each Node on the network If after a specified number of sequential polling cycles the Node does not acknowledge a message the Gateway considers the link with the Node timed out LCD displays on both...

Страница 19: ...devices After any system parameter changes cycle power to cause the devices to resync with the network If a Node device loses synchronization with the network it is programmed to try to acquire sync...

Страница 20: ...ling mode within RUN to freeze the I O status on the LCD display for the device in question Verify that when the input device changes state or changes value the LCD mirrors the behavior Also verify th...

Страница 21: ...X80 BWA HW 003 Tape PFTE Sealant BWA HW 004 Screws Cover Mount 8 32 x 3 4 18 8 SS Power DX81 Battery Pack Kit DX81 with mounting hardware DX121 Battery Pack Kit DX121 6 cells BWA BATT 001 Replacement...

Страница 22: ...rdance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does c...

Страница 23: ...and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular...

Страница 24: ...ring the warranty period This warranty does not cover damage or liability for the improper application of Banner products This warranty is in lieu of any other warranty either expressed or implied CAU...

Отзывы: