Zero = Near
(Default Setting)
Shift = Off
=
=
Zero = Far
Shift = Off
=
=
Zero = Far
Shift = On
=
=
Display Reference
Display Reference
50 mm
50 mm
50 mm
Display Reference
Display Reference
Display Reference
100
0
200
300
mm
0
-100
100
200
mm
0
-100
100
200
mm
100
0
200
300
mm
200
0
100
300
mm
200
0
100
300
mm
Display Reference
Figure 15. Example Zero and Shift settings
3.2.11 Offset
Use this menu to set an offset from the taught surface. This menu is available only if one-point window (foreground suppression)
mode or one-point background suppression mode is selected. For Channel 2, the output must be set to light operate or dark
operate.
Note:
The number that follows
ofS
on the display indicates which channel is selected.
The offset is automatically calculated or manually
defined
as a consistently applied value.
Auto
is the default option. Use +/- to
select a value. Values increase or decrease by 0.1 mm (100/110 mm models) or 0.2 mm (300/310/600/610 mm models).
For BGS mode, the default is
Auto
because the Q4X automatically selects where to position the switch point. For FGS mode, the
default is 0 because the window is centered around the taught target.
A positive offset value always shifts the switch point location or the FGS window towards the sensor.
The taught surface must be inside of the
defined
sensing range. When the teach mode is set to FGS, some portion of the window
must be located within the sensing range. When the teach mode is set to BGS, the offset value must be within the
defined
sensing
range. If an offset value falls outside of the sensing range, a message displays. See the applicable TEACH procedure for more
information.
Q4X Stainless Steel Laser Sensor with Dual Discrete Outputs and IO-Link
www.bannerengineering.com - Tel: 763.544.3164
15