5.3 Performance Curves—Flush Mount Models
Minimum Separation Distance Between Target and Background for: Uniform and Non-Uniform Targets
110 mm Models
310 mm Models
Minimum Separation T
arget to Background
(mm)
Dimension Y
Distance to Target (mm)
Dimension X
0
2
4
6
8
10
12
14
16
18
20
22
0
25
50
75
100
125
150
175
200
225
250
275
300
325
Matte targets with uniform
reflectivity: 6% to 90%
Target
Switch Point
Distance
Background
X
Y
Matte targets with a non-uniform
reflectivity: 6% to 90%
Minimum Separation T
arget to Background
(mm)
Dimension Y
Distance to Target (mm)
Dimension X
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
0
25
35
50
75
100
125
Matte targets with a non-uniform
reflectivity: 6% to 90%
Matte targets with uniform
reflectivity: 6% to 90%
Flush Mount Models
110
35
310
610
610 mm Models
Minimum Separation T
arget to Background
(mm)
Dimension Y
Distance to Target (mm)
Dimension X
0
2
4
6
8
10
12
14
16
18
20
22
0
100
35
200
300
400
500
600
Matte targets with uniform
reflectivity: 6% to 90%
Matte targets with a non-uniform
reflectivity: 6% to 90%
Figure 24. Minimum Object Separation Distance (90% to 6%
reflectance)
Q4X Stainless Steel Laser Sensor with Dual Discrete Outputs and IO-Link
www.bannerengineering.com - Tel: 763.544.3164
35