Method
Action
Result
Push Button
Present the target. The sensor-to-target distance must be within the
sensor's range.
The target's measurement value
displays.
Remote Input
2. Start the TEACH mode.
Method
Action
Result
Push Button
Press and hold
TEACH
for longer than 2 seconds.
Light Operate
and
flash
alternately
on the display. The BGS indicator
flashes.
Dark Operate
and
flash
alternately
on the display. The BGS indicator
flashes.
Remote Input
No action required.
N/A
3. Teach the sensor.
Method
Action
Result
Push Button
Press
TEACH
to teach the target.
The new switch point
flashes
rapidly
and the sensor returns to Run mode.
Remote Input
Single-pulse the remote input.
T
Table 6: Expected TEACH Behavior for One-Point Background Suppression
See
Figure 23
on page 34 for the minimum object separation.
Condition
TEACH Result
Display
One valid TEACH point
If an Offset is applied, the TEACH
point is still valid
Sets a switch point in front of the taught distance
by the vertical minimum object separation.
The switch point distance
flashes
on
the display.
One invalid TEACH point
Sets a switch point at the following location:
Model
Switch Point
100 mm threaded barrel models
75
300 mm threaded barrel models
200
600 mm threaded barrel models
400
110 mm
flush
mount models
85
310 mm
flush
mount models
210
610 mm
flush
mount models
410
and the switch point distance
flash
alternately on the display.
Q4X Stainless Steel Laser Sensor with Dual Discrete Outputs and IO-Link
26