Condition
TEACH Result
Display
Two invalid TEACH points
Sets a switch point at the following location:
Model
Switch Point
100 mm threaded barrel models
99
300 mm threaded barrel models
290
600 mm threaded barrel models
590
110 mm
flush
mount models
109
310 mm
flush
mount models
300
610 mm
flush
mount models
600
and the switch point distance
flash
alternately on the display.
3.6.2 Dynamic Background Suppression
Dynamic TEACH sets a single switch point during machine run conditions. Dynamic TEACH is recommended for applications
where a machine or process may not be stopped for teaching. The sensor takes multiple samples and the switch point is set
between the minimum and the maximum sampled distances.
2
Press and Hold
> 2s
3
Switch
Point
Value
1
5
4
Press to start
sampling
Press to stop
sampling
Figure 18. Dynamic Background Suppression
Note:
The sensor must be set to
=
to use the following instructions. The DYN indicator is amber to
indicate Dynamic TEACH mode.
Note:
To program the sensor using remote input, remote input must be enabled (
=
).
1. Present the target.
Method
Action
Result
Push Button
Present the
first
target. The sensor-to-target distance must be within the
sensor's range.
The target's measurement value
displays.
Remote Input
2. Start the TEACH mode.
Method
Action
Result
Push Button
Press and hold
TEACH
for longer than 2 seconds.
and
flash
alternately
on the display. The DYN indicator
flashes.
Remote Input
No action required.
N/A
3. Teach the sensor.
Q4X Stainless Steel Laser Sensor with Dual Discrete Outputs and IO-Link
www.bannerengineering.com - Tel: 763.544.3164
21