Action
Result
Five-pulse the remote input.
T
T
T
T
T
T
T
T
T
"TchSPt Teaching" displays while the
sensor is being taught.
TEACH Accepted
The new value displays on the second line
of the display, flashes, and the sensor
returns to Run mode.
TEACH Not Accepted
"FAIL" flashes, the sensor returns to step 3,
and "RMT TCH" displays.
3.5.6 Adjust Switch Point
The AdjSPt option manually adjusts the value of the switch point threshold for the discrete output when the sensor is in
Switch mode. The value is adjustable within the sensor's range. This menu is not available when the sensor is in Window,
Alarm, or Health mode.
Remote Input: Not available
Default: 50 mm
3.5.7 Mode
The Mode option sets the output to the desired mode.
Navigate: MENU > Dx_OUT > Mode
Remote Input: Available
Default: Wnd
mode
The following table describes the sensor modes.
Mode
Description
Alarm
Alarm Mode: The Discrete Output is Off while a target is detected by the sensor at any distance.
When a loss of signal occurs, the Discrete Output is On.
This mode has no associated thresholds.
Health
Health Mode: The Discrete Output is On while a target is detected by the sensor at any distance.
When a loss of signal occurs, the Discrete Output is Off.
This mode has no associated thresholds.
Switch
Switch Mode: The Discrete Output is On while a target is detected nearer than the switch point threshold.
When a target is detected farther than the switch point threshold or the signal is lost, the Discrete Output is Off.
Switch
Switch Mode: The Discrete Output is Off while a target is detected nearer than the switch point threshold.
When a target is detected farther than the switch point threshold or the signal is lost, the Discrete Output is On.
Wnd
Window Mode: The Discrete Output is On while a target is detected between the SPt1 and SPt2 thresholds. (Default)
When a target is detected outside the SPt1 and SPt2 thresholds or the signal is lost, the Discrete Output is Off.
Wnd
Window Mode: The Discrete Output is Off while a target is detected between the SPt1 and SPt2 thresholds.
When a target is detected outside the SPt1 and SPt2 thresholds or the signal is lost, the Discrete Output is On.
PFM
The discrete is pulsed at a frequency between 100 Hz and 600 Hz and is scaled proportional to the sensor's
D2_OUT Measurement span. Targets outside of the measurement span or a loss of signal pulse at 50 Hz.
Remote Input Instructions
1. Access the setup mode.
Action
Result
Double-pulse the remote input.
T
T
T
"REMOTE SETUP" displays.
L-GAGE
®
LTF Time of Flight Laser Distance Sensor with IO-Link
www.bannerengineering.com - Tel: + 1 888 373 6767
17