3.2 Sensor Menu (MENU)
Access the Sensor Menu by pressing Enter
from Run mode. The Sensor Menu is also accessible from the Quick Menu:
navigate to MENU and press Enter
. The Sensor Menu includes several submenus that provide access to view and
change sensor settings and to view sensor information.
3.3 Remote Input
Use the remote input to program the sensor remotely. The remove input is disabled by default. Activate remote input using
the buttons to navigate to the Input Type menu option.
The remote input provides limited programming options and is Active Low by default. For Active Low, connect the gray
input wire to ground (0 V dc), with a remote switch connected between the wire and ground. To use the Active High
function, configure the sensor for Active High using the buttons on the sensor, then connect the gray input wire to V+ (12 to
30 V dc). Pulse the remote input according to the diagram and the instructions provided in this manual.
The length of the individual programming pulses is equal to the value T: 0.04 seconds ≤ T ≤ 0.8 seconds.
Exit remote programming modes by holding the remote input low for > 2 seconds, or waiting for the automatic 60-second
timeout, or by pressing and holding Escape
for 2 seconds. The sensor returns to Run mode without saving any new
settings.
L-GAGE
®
LTF Time of Flight Laser Distance Sensor with IO-Link
www.bannerengineering.com - Tel: + 1 888 373 6767
9