Window Size
The D_OUT > TchMid > WndSize option sets the window size that the Midpoint TEACH uses to set the setpoint one and
setpoint two thresholds.
The taught surface must be inside the defined sensing range, and at least one setpoint (with offset applied, if any) must be
located within the sensing range.
Parameters
LTF12
LTF24
Window Size Minimum
10 mm
10 mm
Window Size Maximum
11950 mm
23950 mm
Range
50 mm to 12000 mm
50 mm to 24000 mm
Default Window Size
20 mm
20 mm
Remote Input: Available
1. Access the setup mode.
Method
Action
Result
Push Button
"WndSize" and the current window
size value display.
Remote Input
a. Double-pulse the remote input to enter
setup mode.
b. Three-pulse the remote input to enter
window size mode.
T
T
T
T
T
T
T
T
a. "REMOTE SETUP" displays.
b. "WndSize" and the current value
display.
2. Set the window size.
Method
Action
Result
Push Button
a. Use Down
and Up
to set the desired window size—the
value changes in increments of 2.
b. Press Enter
to save the new value.
a. "WndSize" and the new value
display.
b. The new value flashes and returns
to "TchMid WndSize".
Remote Input
(Sets A_OUT
and D_OUT
window Size)
Pulse the remote input 1 to 6 times to select the desired window size.
Pulses
Window Size
LTF12
LTF24
1
10 mm
10 mm
2
20 mm
20 mm
3
100 mm
100 mm
4
500 mm
500 mm
5
2000 mm
2000 mm
6
11950 mm
23950 mm
The new value flashes and the sensor
returns to Run mode.
TEACH Midpoint
The TchMdPt option sets the midpoint that determines the actual measurement window.
Navigate: MENU > Dx_OUT > TchMid > TchMdPt
Remote Input: Available
Button Instructions
1. Present the target.
L-GAGE
®
LTF Time of Flight Laser Distance Sensor with IO-Link
14
www.bannerengineering.com - Tel: + 1 888 373 6767