SKU: AEOEZW164

 

Quickstart

This is a secure Sound Switch for Europe. To run this device please connect it to your mains power supply. 1. Set your Z-Wave Controller into its 

‘

Add

Device

‘

 mode in order to add siren into your Z-Wave system. Refer to the Controller

‘

s manual if you are unsure of how to perform this step.

2. Power on siren via the provided power adapter; its LED will be breathing white light all the time.
3. Click siren Action Button once, it will quickly flash white light for 30 seconds until siren is added into the network. It will become constantly bright white
light after being assigned a NodeID.
4. If your Z-Wave Controller supports S2 encryption, enter the first 5 digits of DSK into your Controller

‘

s interface if/when requested. The DSK is printed

on Siren

‘

s housing.

5. If Adding fails, it will slowly flash white light 3 times and then become breathing white light; repeat steps 1 to 4. Contact us for further support if needed.
6. If Adding succeeds, it will quickly flash white light 3 times and then become off. Now, Siren is a part of your Z-Wave home control system. You can
configure it and its automation via your Z-Wave system; please refer to your software

‘

s user guide for precise instructions.

Note:If Action Button is clicked again during the Learn Mode, the Learn Mode will exit. At the same time, Indicator Light will extinguish immediately, and
then become breathing white light.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer,
distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this
equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources. 

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and
every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is
not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-
Wave device regardless of brand and origin 
as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this
device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level
of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

- S2 Security.- Not only a siren, but also can be used as a doorbell via setting.- Can be wireless controlled by more Button, up to 3.- Longer Button control
distance, up to 120m.- Built-in multiple tones, up to 30.- Built-in multiple adjustable Light Effect.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do
this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended
to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.

To complete the reset process manually, press and hold the Action Button for at least 20s. The LED indicator will quickly flash white light 3 times and then become
breathing white light, which indicates the reset operation is successful.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the
assembly of the product, the voltage network has to be switched off and ensured against re-switching.

Содержание AEOEZW164

Страница 1: ...e Quickstart section Z Wave ensures a reliable communication by reconfirming every message two way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter This device and every other certified Z Wave device can be used together with any other certified Z Wave device regardless of brand and ...

Страница 2: ...erPairing 2ButtonMode ClickActionButton5timesquicklywilltriggerPairing 3ButtonMode 2 ObserveSirenIndicatorLighttomakesurewhichButtoniswaitingforpairing WhenPairing 1ButtonModeistriggered SirenIndicatorLightwillbright1timeON0 5sOFF1s andthenbecomeconstantlybrightwhitelight indicatingthatPairing 1ButtonModehas alreadytriggered Pairingtimeisupto10seconds Inthistimeperiod userMUSTmanuallyclickRing But...

Страница 3: ...aying tone or stops playing tone Nodes associated are controlled and will receive a Basic Set CC 3 5 When Endpoint 2 starts playing tone or stops playing tone Nodes associated are controlled and will receive a Basic Set CC 4 5 When Endpoint 3 starts playing tone or stops playing tone Nodes associated are controlled and will receive a Basic Set CC 5 5 When Endpoint 4 starts playing tone or stops pl...

Страница 4: ...figure the Light Effect and Tone Effect for Endpoint 6 Environment Parameter 7 Configure the Light Effect and Tone Effect for Endpoint 7 Security Please refer to the Product Manual for more details Size 4 Byte Default Value 67108864 Setting Description 16777216 2147483647 Configure the Light Effect and Tone Effect for Endpoint 7 Security Parameter 8 Configure the Light Effect and Tone Effect for Endpo...

Страница 5: ...t Effect will be displayed in a loop until stop playing tone Parameter 22 Configure 7 Light Effect Please refer to the Product Manual for more details Size 4 Byte Default Value 553648129 Setting Description 0 2147483647 The Light Effect is displayed cyclically and the maximum display duration is equal to the total duration of the tone playback In other words the Light Effect will be displayed in a ...

Страница 6: ...0x00 4 When Endpoint 4 starts playing tone send Basic Set 0x00 When Endpoint 4 stops playing tone send Basic Set 0xFF Parameter 36 Configure how to send Basic Set to nodes in Group 6 Size 1 Byte Default Value 3 Setting Description 0 Dont send Basic Set 1 When Endpoint 5 starts playing tone send Basic Set 0xFF When Endpoint 5 stops playing tone dont send Basic Set 2 When Endpoint 5 starts playing to...

Страница 7: ...ly 1 Can trigger unpairing multiple Buttons at one time 2 User does not need to do anything to Button 3 Indicator Light will quickly flash white light 3 times when Unpairing Button Mode finishes Size 1 Byte Default Value 0 Setting Description 1 Tigger Unpairing 1 Button Mode 2 Tigger Unpairing 2 Button Mode 3 Tigger Unpairing 2 and 1 Button Mode 4 Tigger Unpairing 3 Button Mode 5 Tigger Unpairing 3 ...

Страница 8: ...ftware version Parameter 53 Get the information of 2 Button Read Only This parameter does not restore to the default value when Siren is removed from the network or reset the factory settings Size 4 Byte Default Value 0 Setting Description 0 2 Button is unpaired 1 134217727 Information about 2 Button including battery voltage unit is mV and software version Parameter 54 Get the information of 3 Bu...

Страница 9: ... Supported Command Classes Association Grp Info Association V2 Basic Configuration Device Reset Locally Firmware Update Md V4 Manufacturer Specific V2 Multi Channel Association V3 Multi Channel V4 Notification V8 Powerlevel Security Security 2 Sound Switch Supervision Transport Service V2 Version V2 Zwaveplus Info V2 Controlled Command Classes Basic Explanation of Z Wave specific terms Controller is a...

Страница 10: ...rolled device Wakeup Notification is a special wireless message issued by a Z Wave device to announces that is able to communicate Node Information Frame is a special wireless message issued by a Z Wave device to announce its capabilities and functions c 2020 Z Wave Europe GmbH Antonstr 3 09337 Hohenstein Ernstthal Germany All rights reserved www zwave eu The template is maintained by Z Wave Europe...