Input Polarity
Main Menu > System > Discrete I/O > Input Polarity
The iVu has two input signals - —Trigger and Remote Teach. Both these signals are edge sensitive. The operation of
these signals is dependent on the Input Polarity setting.
• Low To High — The Trigger and Remote Teach are detected on a low to high transition of the signal. High
• To Low — The Trigger and Remote Teach are detected on a high to low transition of the signal.
Input Pullup Screen
Main Menu > System > Discrete I/O > Input Pullup
By default, the Input Pullup is disabled. If the device used to trigger and remote teach the iVu sensor is a Sinking device
(NPN) then you will only need to enable Input Pullup here if that device does not have its own pullup resistor. Other-
wise, this should be disabled.
I/O Type Screen
iVu Plus User's Manual
42
www.bannerengineering.com - tel: 763-544-3164