Sample map demonstrating string values:
Memory Map: Default
NOTE: ControlLogix string format. "iVu Plus Image Sensor"
Memory Map: "Style" changed to ASCII
All data is initially transferred as "INT" data type. An ASCII string looks like gibberish in this format. Changing the "style" to ASCII
instead of "Decimal" reveals the correct string data.