2.3 Major Features
2.3.1 Demo Mode
The first time you power up the iVu Plus TG sensor, it starts in Demo Mode. Demo Mode uses stored images and inspection parameters
that demonstrate how the sensor is set up without having to worry about focus, lighting, or triggers. In this mode, you can learn how to
make adjustments working with the four sensor types while observing how the adjustments affect the sensor results. To exit Demo Mode,
go to Main Menu > System > Sensor Mode and select Live from the drop-down list. When you exit Demo Mode, the sensor reboots into
its normal operating mode with default settings.
NOTE: You may return to Demo Mode any time by going to Main Menu > System > Sensor Mode and se-
lecting Demo.
2.3.2 Sensor Types
The iVu Plus TG sensor includes four Sensor Types:
Area Sensor
An Area type sensor is used to ensure that a feature, or some features, are present on a part. When setting up the sensor for an Area
inspection, a feature, such as a drilled hole, is identified as well as the size (area) expected. If there is more than one of the identified
iVu Plus User's Manual
14
www.bannerengineering.com - tel: 763-544-3164
Online Only - rev. B
Содержание iVu PLUS TG
Страница 1: ...iVu Plus User s Manual Online Only rev B 1 25 2012 ...
Страница 105: ...iVu Plus User s Manual Online Only rev B www bannerengineering com tel 763 544 3164 105 ...
Страница 106: ...2 Select Module iVu Plus User s Manual 106 www bannerengineering com tel 763 544 3164 Online Only rev B ...