The sensor triggers from high to low, and Remote Teach behaves electrically like trigger.
NOTE: If the device used to trigger or remote teach the iVu Plus TG is a sinking device (that is, NPN), then
there are two options regarding the use of a pull-up resistor:
Option 1: Put a pull-up resistor, rated approximately 1k ohm, between the sensor's positive (+) voltage and
the sensor's input as shown below.
Trigger Input
Remote Teach Input
iVu
Pullup Resistor
1k ohm
NPN
VCC
Sinking
Option 2: Enable the Input Pullup in the iVu Plus TG software ( Main Menu > System > Discrete I/O > Input
Pullup ).
iVu Output Waveforms
PNP Outputs
Ready
(Pass)
(Fail)
(Pass)
(Pass)
(Fail)
(Pass)
Function
Strobe Out
(Configure as External
& Expose Based)
Outputs 1,2, and 3
(Set as Active Pass)
Outputs 1, 2, and 3
(Set as Active Fail)
NPN Outputs
iVu Plus User's Manual
Online Only - rev. B
www.bannerengineering.com - tel: 763-544-3164
13
Содержание iVu PLUS TG
Страница 1: ...iVu Plus User s Manual Online Only rev B 1 25 2012 ...
Страница 105: ...iVu Plus User s Manual Online Only rev B www bannerengineering com tel 763 544 3164 105 ...
Страница 106: ...2 Select Module iVu Plus User s Manual 106 www bannerengineering com tel 763 544 3164 Online Only rev B ...