RS-232 Command and Control
An HD6 may be controlled externally using the rear panel RS-232 I/O RJ-45 connector. An external control
system may be directly connected to the HD6 to control either the HD6 or both HD6 and a CT Receiver. For use
in an external RS-232 automation control system, the control device must connect to the RS-232 I/O RJ-45
connector on the back of the HD6. A distilled list of RS-232 commands for use with a default HD6 system setup
is provided on the following pages.
Note: For use with an HD6 Linked to a CT Series Receiver, the external control device must treat the linked pair
as a single CT Receiver device. All RS-232 control shall use the appropriate CT Receiver BKC-DIP commands.
This applies regardless of the fact that the RS-232 control system is connected to the HD6 RS-232 I/O
connector. All BKC-DIP commands shall pass through the HD6 to the linked CT Receiver. The Linked CT
Receiver handles all control of the HD6 through the CT RS-232 Link cable. Complete HD6 BKC-DIP informa-
tion may be found in the HD6 product appendices.
HD6 BKC-DIP (Abbreviated List)
Shown with default settings: Transmit ID = 00, Receive ID = 00, Zone A = code-set 11, Zone B = code-set 12,etc.
Power Commands
On, Off and Toggle
(00, S, I, 0B=40;)
Power On Zone 11
(00, S, I, 0E=40;)
Power On Zone 14
(00, S, I, 0C=40;)
Power On Zone 12
(00, S, I, 0F=40;)
Power On Zone 15
(00, S, I, 0D=40;)
Power On Zone 13
(00, S, I, 10=40;)
Power On Zone 16
(00, S, I, 00=40;)
Power On Zone 0 (WHOLE-HOUSE)
(00, S, I, 0B=80;)
Power Off Zone 11
(00, S, I, 0E=80;)
Power Off Zone 14
(00, S, I, 0C=80;)
Power Off Zone 12
(00, S, I, 0F=80;)
Power Off Zone 15
(00, S, I, 0D=80;)
Power Off Zone 13
(00, S, I, 10=80;)
Power Off Zone 16
(00, S, I, 00=80;)
Power Off Zone 0 (WHOLE-HOUSE)
(00, S, I, 0B=45;)
Power Toggle Zone 11
(00, S, I, 0E=45;)
Power Toggle Zone 14
(00, S, I, 0C=45;)
Power Toggle Zone 12
(00, S, I, 0F=45;)
Power Toggle Zone 15
(00, S, I, 0D=45;)
Power Toggle Zone 13
(00, S, I, 10=45;)
Power Toggle Zone 16
(00, S, I, 00=45;)
Power Toggle Zone 0 (WHOLE-HOUSE)
Input Select Commands
ZONE A
(code-set 11)
(00, S, I, 0B=A0;)
Select IN 1 for Zone 11
(00, S, I, 0B=52;)
Select IN 6 for Zone 11
(00, S, I, 0B=90;)
Select IN 2 for Zone 11
(00, S, I, 0B=D0;)
Select IN 7 for Zone 11
(00, S, I, 0B=60;)
Select IN 3 for Zone 11
(00, S, I, 0B=E0;)
Select IN 8 for Zone 11
(00, S, I, 0B=B0;)
Select IN 4 for Zone 11
(00, S, I, 0B=76;)
Select IN 9 for Zone 11
(00, S, I, 0B=F0;)
Select IN 5 for Zone 11
(00, S, I, 0B=5A;)
Select D-IN for Zone 11
ZONE B
(code-set 12)
(00, S, I, 0C=A0;)
Select IN 1 for Zone 12 (00, S, I, 0C=52;)
Select IN 6 for Zone 12
(00, S, I, 0C=90;)
Select IN 2 for Zone 12 (00, S, I, 0C=D0;)
Select IN 7 for Zone 12
(00, S, I, 0C=60;)
Select IN 3 for Zone 12 (00, S, I, 0C=E0;)
Select IN 8 for Zone 12
(00, S, I, 0C=B0;)
Select IN 4 for Zone 12
(00, S, I, 0C=76;)
Select IN 9 for Zone 12
(00, S, I, 0C=F0;)
Select IN 5 for Zone 12 (00, S, I, 0C=5A;)
Select D-IN for Zone 12
SERIAL CONTROL COMMANDS