background image

26

Color Bar Video Test Generator

The HD6 has a built in 

Color Bar Video Test Generator

for use with in-system testing and troubleshooting of all

zone video outputs. When set to on, the HD6 sends NTSC color bars out the designated zone video output(s).
The color bar generator may be set on and off in Zones A-F in any combination. The color bar generator may
be set using IR Data or BKC-DIP RS-232 commands.

For use with IR Data, use the code-set (zone ID) of the desired zone to test and 

send 

MENU

then 

6

then 

5

then

Right

to turn on the color bar generator, 

send 

EXIT

to turn off the generator. All Zones A-F may be simultane-

ously set on and off using the 

WHOLE-HOUSE 

code-set 0 0 0. 

IR Data Color Bar Generation examples:
Using code-set 0 0 0 WHOLE-HOUSE

send 

MENU

then 

6

then 

5

then 

Right

to set the color bar generator on in all Zones A-F.

send 

EXIT

to set the color bar generator off in all Zones A-F.

Using code-set 0 1 1

send 

MENU

then 

6

then 

5

then 

Right

to set the color bar generator on in Zone A (default is zone 11).

send 

EXIT

to set the color bar generator off in Zone A (default is zone 11).

BKC-DIP RS-232 examples:
Color bar generation may be set using BKC-DIP eXecutive command 9.

send 

(FF,X,9,00=1;)

to set the color bar generator on in all zones using WHOLE-HOUSE zone 0.

send 

(FF,X,9,00=0;)

to set the color bar generator off in all zones using WHOLE-HOUSE zone 0.

send 

(FF,X,9,0B=1;)

to set the color bar generator on in Zone A (default is zone 11).

send 

(FF,X,9,0B=0;)

to set the color bar generator off in Zone A (default is zone 11).

Reset Unit to Factory Default

The HD6 allows the capability to be restored to a factory default configuration. Reset to factory default may be
set using IR Data or BKC-DIP RS-232 commands.

For use with IR Data, use any code-set (zone ID) currently set in the HD6 and 

send 

EXIT

then 

MENU

then 

5

then 

RIGHT

then 

RIGHT

then 

ENTER

.

Using code-set 0 0 0 WHOLE-HOUSE

send 

EXIT

then 

MENU

then 

5

then 

RIGHT

then 

RIGHT

then 

ENTER

to restore factory default settings.

For use with BKC-DIP RS-232:
Reset to factory default may be set using BKC-DIP eXecutive command 7.

send 

(FF,X,7;)

to restore factory default settings.

Flash Memory Update and Upgrade

As new software improvements become available for the HD6, the

Flash Memory Updat

e feature allows the

HD6 operating system to be

Update

d using the rear panel ETHERNET port. In addition, the HD6 allows a

methodology to

Upgrad

e the operating system for use with additional B&K software features. Visit

www.bkcomp.com

for HD6 software options and availability.

UTILITIES

S

B

I M P LY

E T T E R !

B K

&

Содержание HD6

Страница 1: ...B K Components Ltd HD6 6 Zone Transcoding High Definition Video Switcher User Manual S B IMPLY ETTER B K 13840 040106...

Страница 2: ...ls Through upgrades B K delivers exceptional value to its customers But what is upgradeability Upgradeability is not a guarantee we define it as a philosophy of designing and manufacturing products so...

Страница 3: ...peration using IR or Keypad 12 Stand Alone Operation over RS 232 12 MZ 128 CT Series IR Remote Controller 13 BKcSuite Setup 14 BKcSuite Group Code Set and Zone Setup 19 BKcSuite Input Settings Setup 2...

Страница 4: ...tning in your area Prevent damage to the power cord Replace the power cord if it becomes damaged in any way Always grasp the plug on the power cord when plugging or unplugging the preamplifier from th...

Страница 5: ...o Source Output 9 buffered video pass through outputs These video outputs allow for easy system expansion when it is desired to support more than six zones Dedicated Video Input 6 inputs each zone has...

Страница 6: ...he HD6 includes an anodized aluminum faceplate available in various configurations The HD6 front panel is comprised of an LED power indicator and master power On Off switch 17 Black faceplate Standard...

Страница 7: ...video CVBS and S Video Y C are transcoded to component video Y Pr Pb 5 Dedicated Video Source Inputs Each of the six video zones has one local high definition source Local source connections must be h...

Страница 8: ...gether and attached to the cabinet rack on the opposite side of the signal cabling Any component without enough slack in the power wire to enable rotating it or extracting it should have its length ex...

Страница 9: ...three types of video source devices composite video S Video and component video Component video is passed directly to the appropriate zone output When a composite or S Video is selected it is convert...

Страница 10: ...outputs Video resolution will remain unchanged when transcoding from S Video to component Composite Video Connection For use with composite video the composite video signal must be connected to the R...

Страница 11: ...e same fashion as the common video source inputs 1 through 9 No video scaling is applied to dedicated input signals BUFFERED VIDEO SOURCE OUTPUTS One buffered line output is provided for each source i...

Страница 12: ...re mounting in a wall plate is not possible The diagram below shows the HD6 connected using RCA termination in zones A C and CAT5 termination with LB10W CAT5 RCA local decora video conversion modules...

Страница 13: ...the front panel to match the total installed length of Category 5e cable LB20F a closed box conversion module allows for a myriad of mounting options The HD6 CAT5 video drive cable must always connec...

Страница 14: ...an external eye or keypad and an IR input compatible with IR data between 5 and 12 volts This is strictly a one way connection The HD6 is not capable of providing display feedback or page jumps on the...

Страница 15: ...set 1 Install 4 AAA batteries into the remote Observe polarity 2 Press and hold the B K and MUTE buttons simultaneously for two seconds The LED will light up solid red and stay illuminated 3 Enter th...

Страница 16: ...Switchers The installation path for BKcSuite is c program files B K Components Ltd BkcSuite exe Warning PC requirements 128MB RAM Pentium grade or better processor Windows 98SE operating system or gr...

Страница 17: ...cable into the HD6 RS 232 I O serial port USB to Serial Adapter USB to serial adapters are a convenient solution for connecting to a computer that has no available DB 9 type serial port Install any r...

Страница 18: ...e Open BKcSuite A V Setup from BKTask 2 When Tool Suite is first opened the Device Investigator automatically scans to find a connected B K product Choose select product for operation without a connec...

Страница 19: ...s are described below Open the Advanced System Editor to program the system parameters of your HD6 Select another B K Virtual Product to setup Run the Device Investigator so that you may connect to th...

Страница 20: ...nected to a hardware Zone A F all devices may be programmed identically using code set 1 2 8 and control only the hardware zone it is connected to However a more powerful and versatile install may be...

Страница 21: ...dividual zone A F When working with a system with more than one HD6 assign code sets 021 to 026 to the second HD6 031 to 036 to the third unit and so on 3 Title Name the group zone with a name that wi...

Страница 22: ...A F thus they are common shared video inputs BKC DIP communication may be used to view these names and other system parameters for use in an external automation system 2 Dedicated Video Input Names Ti...

Страница 23: ...deo inputs are set to Yes in a default configuration Set to No when there is no video source to be connected to this zone s dedicated input 2 Common Zone Inputs Hardware Zones A F have have nine commo...

Страница 24: ...an one B K product from the same data port 4 RS 232 Echo Enabled For use with an external control system talking to the HD6 via RS 232 Echo will repeat RS 232 transmission received through the main RJ...

Страница 25: ...Power On Zone 14 00 S I 0C 40 Power On Zone 12 00 S I 0F 40 Power On Zone 15 00 S I 0D 40 Power On Zone 13 00 S I 10 40 Power On Zone 16 00 S I 00 40 Power On Zone 0 WHOLE HOUSE 00 S I 0B 80 Power Of...

Страница 26: ...lect IN 6 for Zone 15 00 S I 0F 90 Select IN 2 for Zone 15 00 S I 0F D0 Select IN 7 for Zone 15 00 S I 0F 60 Select IN 3 for Zone 15 00 S I 0F E0 Select IN 8 for Zone 15 00 S I 0F B0 Select IN 4 for Z...

Страница 27: ...Video Output Impedance 75 ohm Video Output Signal 1 2 Volts p p 75 ohm terminated Zone Video Output RCA Component Y Pb Pr Zone Outputs 6 Video Output Signal 1 2 Volts p p 75 ohm terminated Video Band...

Страница 28: ...ve command 9 send FF X 9 00 1 to set the color bar generator on in all zones using WHOLE HOUSE zone 0 send FF X 9 00 0 to set the color bar generator off in all zones using WHOLE HOUSE zone 0 send FF...