The HD6 component video switcher is a six zone, high definition, video control center. The video switcher is
designed to be an attractive, easy-to-use addition to any Audio/Video system. The HD6 is designed to be a
simple Plug n Play companion to our CT Series of multi-zone receivers. One HD6 may be mated (linked) to one
CT Receiver in a system. 

For use as a stand alone video switcher, the HD6 allows command and control

operation with any of the following rear panel connections

.

1) IR Data, 3 pin Phoenix connector for IR Data Input, GND and +12 VDC out.

2) RS-232 I/O, RJ-45 allows BKC-DIP commands for use with an external automation system.

3) Ethernet , RJ-45 (see 

www.bkcomp.com

for availability and support).

Six Zones of Video Control -

The HD6 has 6 zones of high definition component video distribution for use with

both RCA terminated cable and differential Category 5e (CAT5) cable. 

Video Transcoding -

All 6 zones of the HD6 allow seamless integration and operation with composite, S-Video

and component. The HD6 automatically detects the input video type. Component video is passed through
without processing. Both composite and S-Video are transcoded to component. Resolution of the original video
signal is not altered. 

Note: S-Video must be split into separate Y-C for use with the HD6 RCA inputs. B&K has

available an S-Video -> RCA (Y-C) adapter (B&K p\n 13969

).

Common Source Video Inputs - 

9 general purpose component video inputs are provided. When Linked to a

CT Receiver, these 9 inputs easily provides a component video distribution system that is in sync with the 9 A/V
general purpose inputs on a CT Receiver.

Buffered Video Source Output - 

9 buffered video pass through outputs. These video outputs allow for easy

system expansion when it is desired to support more than six zones.

Dedicated Video Input -

6 inputs, each zone has an additional dedicated video input for use only in that zone.

With a linked CT Receiver, each dedicated input has the capability to be auto-selected when video is detected.

RCA Component Video Distribution -

6 zones of video for use with standard RCA connector terminations.

CAT5 Component Video Distribution -

6 zones of powered differential video drive for use with Category 5e

cable and RJ-45 termination. A B&K LB10W or LB20F video CAT5 -> RCA video conversion module may be
used for converting back to standard RCA connections.

Signal Sensing - 

The HD6 includes circuitry to scan all inputs for the presence of video. This information is

made available to a linked CT Receiver for use with triggering page/events or dedicated input auto-switching. 

RS-232 Control -

An HD6 allows for command and control using RS-232. See the appropriate BKC-DIP appen-

dices for the RS-232 protocol. Typically an HD6 will be controlled via serial information supplied directly from an
RS-232 Linked CT Series Receiver. The HD6 will automatically configure itself to operate with the RS-232
Linked CT Receiver. The HD6 may also be operated stand-alone over the main RS-232 connection.

IR Control - 

A single 3-pin Phoenix-style connector is provided for directly controlling the HD6 using IR. 12 volt

power is supplied from the HD6 and to allow an external IR eye or keypad to be connected.

BKcSuite Interface -

Setup and configuration may be accomplished using BKcSuite interface software avail-

able at 

www.bkcomp.com

.

Gold Plated Connectors - 

Minimum signal loss and degradation.

Ethernet - 

Allows software upgrades and device command and control via TCP/IP.

HD6 FEATURE OVERVIEW

Содержание HD6

Страница 1: ...B K Components Ltd HD6 6 Zone Transcoding High Definition Video Switcher User Manual S B IMPLY ETTER B K 13840 040106...

Страница 2: ...ls Through upgrades B K delivers exceptional value to its customers But what is upgradeability Upgradeability is not a guarantee we define it as a philosophy of designing and manufacturing products so...

Страница 3: ...peration using IR or Keypad 12 Stand Alone Operation over RS 232 12 MZ 128 CT Series IR Remote Controller 13 BKcSuite Setup 14 BKcSuite Group Code Set and Zone Setup 19 BKcSuite Input Settings Setup 2...

Страница 4: ...tning in your area Prevent damage to the power cord Replace the power cord if it becomes damaged in any way Always grasp the plug on the power cord when plugging or unplugging the preamplifier from th...

Страница 5: ...o Source Output 9 buffered video pass through outputs These video outputs allow for easy system expansion when it is desired to support more than six zones Dedicated Video Input 6 inputs each zone has...

Страница 6: ...he HD6 includes an anodized aluminum faceplate available in various configurations The HD6 front panel is comprised of an LED power indicator and master power On Off switch 17 Black faceplate Standard...

Страница 7: ...video CVBS and S Video Y C are transcoded to component video Y Pr Pb 5 Dedicated Video Source Inputs Each of the six video zones has one local high definition source Local source connections must be h...

Страница 8: ...gether and attached to the cabinet rack on the opposite side of the signal cabling Any component without enough slack in the power wire to enable rotating it or extracting it should have its length ex...

Страница 9: ...three types of video source devices composite video S Video and component video Component video is passed directly to the appropriate zone output When a composite or S Video is selected it is convert...

Страница 10: ...outputs Video resolution will remain unchanged when transcoding from S Video to component Composite Video Connection For use with composite video the composite video signal must be connected to the R...

Страница 11: ...e same fashion as the common video source inputs 1 through 9 No video scaling is applied to dedicated input signals BUFFERED VIDEO SOURCE OUTPUTS One buffered line output is provided for each source i...

Страница 12: ...re mounting in a wall plate is not possible The diagram below shows the HD6 connected using RCA termination in zones A C and CAT5 termination with LB10W CAT5 RCA local decora video conversion modules...

Страница 13: ...the front panel to match the total installed length of Category 5e cable LB20F a closed box conversion module allows for a myriad of mounting options The HD6 CAT5 video drive cable must always connec...

Страница 14: ...an external eye or keypad and an IR input compatible with IR data between 5 and 12 volts This is strictly a one way connection The HD6 is not capable of providing display feedback or page jumps on the...

Страница 15: ...set 1 Install 4 AAA batteries into the remote Observe polarity 2 Press and hold the B K and MUTE buttons simultaneously for two seconds The LED will light up solid red and stay illuminated 3 Enter th...

Страница 16: ...Switchers The installation path for BKcSuite is c program files B K Components Ltd BkcSuite exe Warning PC requirements 128MB RAM Pentium grade or better processor Windows 98SE operating system or gr...

Страница 17: ...cable into the HD6 RS 232 I O serial port USB to Serial Adapter USB to serial adapters are a convenient solution for connecting to a computer that has no available DB 9 type serial port Install any r...

Страница 18: ...e Open BKcSuite A V Setup from BKTask 2 When Tool Suite is first opened the Device Investigator automatically scans to find a connected B K product Choose select product for operation without a connec...

Страница 19: ...s are described below Open the Advanced System Editor to program the system parameters of your HD6 Select another B K Virtual Product to setup Run the Device Investigator so that you may connect to th...

Страница 20: ...nected to a hardware Zone A F all devices may be programmed identically using code set 1 2 8 and control only the hardware zone it is connected to However a more powerful and versatile install may be...

Страница 21: ...dividual zone A F When working with a system with more than one HD6 assign code sets 021 to 026 to the second HD6 031 to 036 to the third unit and so on 3 Title Name the group zone with a name that wi...

Страница 22: ...A F thus they are common shared video inputs BKC DIP communication may be used to view these names and other system parameters for use in an external automation system 2 Dedicated Video Input Names Ti...

Страница 23: ...deo inputs are set to Yes in a default configuration Set to No when there is no video source to be connected to this zone s dedicated input 2 Common Zone Inputs Hardware Zones A F have have nine commo...

Страница 24: ...an one B K product from the same data port 4 RS 232 Echo Enabled For use with an external control system talking to the HD6 via RS 232 Echo will repeat RS 232 transmission received through the main RJ...

Страница 25: ...Power On Zone 14 00 S I 0C 40 Power On Zone 12 00 S I 0F 40 Power On Zone 15 00 S I 0D 40 Power On Zone 13 00 S I 10 40 Power On Zone 16 00 S I 00 40 Power On Zone 0 WHOLE HOUSE 00 S I 0B 80 Power Of...

Страница 26: ...lect IN 6 for Zone 15 00 S I 0F 90 Select IN 2 for Zone 15 00 S I 0F D0 Select IN 7 for Zone 15 00 S I 0F 60 Select IN 3 for Zone 15 00 S I 0F E0 Select IN 8 for Zone 15 00 S I 0F B0 Select IN 4 for Z...

Страница 27: ...Video Output Impedance 75 ohm Video Output Signal 1 2 Volts p p 75 ohm terminated Zone Video Output RCA Component Y Pb Pr Zone Outputs 6 Video Output Signal 1 2 Volts p p 75 ohm terminated Video Band...