170
Manual Documentation Number: EIRM-EXTEND-8-1
m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
DOMAIN-NAME Specifies the Domain name of NTP server.
4.
Example:
The following example specifies the IP address (
192.168.1.100
) of NTP
server:
switch_a(config)#ntp server 192.168.1.100
switch_a(config)#
Sync Time:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use
ntp sync-time
command to synchronize time with NTP server.
3.
Command Syntax:
ntp sync-time
4.
Example:
The following example synchronizes time with NTP server:
switch_a(config)#ntp sync-time
switch_a(config)#
Time Zone:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use this command to to set time zone.
3.
Command Syntax:
clock timezone TIMEZONE
TIMEZONE Specifies the time zone. (Please refer the Appendix B)
4.
Example:
The following example sets time zone (Canada/Yukon):