Manual Documentation Number: EIRM-EXTEND-8-1
m
155
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
switch_a(config-if)#dot1x port-control auto
switch_a(config-if)#
Periodic Reauthentication:
Reauthentication Period:
1.
Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
fe1 means port 1.
The
switch_a(config-if)#
prompt will show on the screen.
switch_a(config)#interface fe1
switch_a(config-if)#
2.
Usage:
Use this command to set the interval between reauthorization attempts.
Use
no dot1x timeout re-authperiod
command to delete the interval
between reauthorization attempts.
3.
Command Syntax:
dot1x timeout re-authperiod SECS
no dot1x timeout re-authperiod
SECS <1-4294967295> Specify the seconds between reauthorization
attempts. The default time is 3600 seconds.
4.
Example:
The following example specifies to set the interval
25
seconds between
reauthorization attempts:
switch_a(config)#interface fe1
switch_a(config-if)#dot1x timeout re-authperiod 25
switch_a(config-if)#