switch_a(config)#bridge 1 protocol ring
switch_a(config)#
Set ring port:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use this command to set Ring port 1 and Ring port 2.
3.
Command Syntax:
ring set-port RING_PORT_1 RING_PORT_2
RING_PORT_1 Specify the Ring port 1.
RING_PORT_2 Specify the Ring port 2.
4.
Example:
The following example sets the fe1 and fe2 as Ring port 1 and Ring port 2:
switch_a(config)#ring set-port fe1 fe2
switch_a(config)#