120
Manual Documentation Number: EIRM-EXTEND-8-1
m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
The following example sets the
priority
PRIORITY (
4096
) of bridge
GROUP (
1
):
switch_a(config)#bridge 1 priority 4096
switch_a(config)#
Hello Time (sec) (1..9):
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use this command to set the hello-time, the time in seconds after which (if
this bridge is the root bridge) all the bridges in a bridged LAN exchange
Bridge Protocol Data Units (BPDUs).
3.
Command Syntax:
bridge GROUP hello-time HELLOTIME
no bridge GROUP hello-time
GROUP <1-1> The ID of the bridge group to which this hello time is
assigned.
HELLOTIME <1-9> The hello BPDU interval in seconds.
4.
Example:
The following example sets the
hello-time
HELLOTIME (
9
) of bridge
GROUP (
1
):
switch_a(config)#bridge 1 hello-time 9
switch_a(config)#
Max Age (sec) (6..28):
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use this command to set the max-age for a bridge.
Use the no parameter with this command to restore the default value of
max-age.