WARNING NOTES FOR THE USER HOW TO USE THE BURNER SAFELY
FOREWORD
These warning notes are aimed at ensuring the safe use of the components of heating systems for civil use and the production of hot water. They indicate how to act to
avoid the essential safety of the components being compromised by incorrect or erroneous installation and by improper or unreasonable use. The warning notes provided
in this guide also seek to make the consumer more aware of safety problems in general, using necessarily technical but easily understood language. The manufacturer is
not liable contractually or extra contractually for any damage caused by errors in installation and in use, or where there has been any failure to follow the manufacturer’s
instructions.
GENERAL WARNING NOTES
• The instruction booklet is an integral and essential part of the product and must be given to the user. Carefully read the warnings in the booklet as they contain important
information regarding safe installation, use and maintenance. Keep the booklet to hand for consultation when needed.
• Equipment must be installed in accordance with current regulations, with the manufacturer’s instructions and by qualified technicians. By the term ‘qualified technicians’
is meant persons that are competent in the field of heating components for civil use and for the production of hot water and, in particular, assistance centres authorised
by the manufacturer. Incorrect installation may cause damage or injury to persons, animals or things. The manufacturer will not in such cases be liable.
• After removing all the packaging make sure the contents are complete and intact. If in doubt do not use the equipment and return it to the supplier. The packaging ma
-
terials (wooden crates, nails, staples, plastic bags, expanded polystyrene, etc.) must not be left within reach of children as they may be dangerous to them. They should
also be collected and disposed on in suitably prepared places so that they do no pollute the environment.
• Before carrying out any cleaning or maintenance, switch off the equipment at the mains supply, using the system’s switch or shut-off systems.
• If there is any fault or if the equipment is not working properly, de-activate the equipment and do not attempt to repair it or tamper with it directly. In such case get in touch
with only qualified technicians. Any product repairs must only be carried out by BALTUR authorised assistance centres using only original spare parts. Failure to act as
above may jeopardise the safety of the equipment. To ensure the efficiency and correct working of the equipment, it is essential to have periodic maintenance carried out
by qualified technicians following the manufacturer’s instructions.
• If the equipment is sold or transferred to another owner or if the owner moves and leaves the equipment, make sure that the booklet always goes with the equipment so
it can be consulted by the new owner and/or installer.
• For all equipment with optionals or kits (including electrical), only original accessories must be used.
BURNERS
• This equipment must be used only for its expressly stated use: applied to boilers, hot air boilers, ovens or other similar equipment and not exposed to atmospheric agents.
Any other use must be regarded as improper use and hence dangerous.
• The burner must be installed in a suitable room that has ventilation in accordance with current regulations and in any case sufficient to ensure correct combustion
• Do not obstruct or reduce the size of the burner’ air intake grills or the ventilation openings for the room where a burner or a boiler is installed or dangerous mixtures of
toxic and explosive gases may form.
• Before connecting the burner check that the details on the plate correspond to those of the utility supplies (electricity, gas, light oil or other fuel).
• Do not touch hot parts of the burner. These, normally in the areas near to the flame and any fuel pre-heating system, become hot when the equipment is working and
stay hot for some time after the burner has stopped.
• If it is decided not to use the burner any more, the following actions must be performed by qualified technicians:
a) Switch off the electrical supply by disconnecting the power cable from the master switch.
b) Cut off the fuel supply using the shut-off valve and remove the control wheels from their position.
c) Render harmless any potentially dangerous parts.
Special warning notes
• Check that the person who carried out the installation of the burner fixed it securely to the heat generator so that the flame is generated inside the combustion chamber
of the generator itself.
• Before starting up the burner, and at least once a year, have qualified technicians perform the following operations:
a) Set the burner fuel capacity to the power required by the heat generator.
b) Adjust the combustion air flow to obtain combustion yield of at least the minimum set by current regulations.
c) Carry out a check on combustion to ensure the production of noxious or polluting unburnt gases does not exceed limits permitted by current regulations.
d) Check the adjustment and safety devices are working properly.
e) Check the efficiency of the combustion products exhaust duct.
f) Check at the end of the adjustments that all the adjustment devices mechanical securing systems are properly tightened.
g) Make sure that the use and maintenance manual for the burner is in the boiler room.
• If the burner repeatedly stops in lock-out, do not keep trying to manually reset but call a qualified technicians to sort out the problem.
• The running and maintenance of the equipment must only be carried out by qualified technicians, in compliance with current regulations.
Содержание TBG 45
Страница 2: ......
Страница 4: ......
Страница 5: ...0006081362_200906...
Страница 6: ......
Страница 80: ...2 18 0006081362_200906 BALTUR a b c a b c d e f g...
Страница 81: ...3 18 0006081362_200906 2 RC a b c d e a b a b c d...
Страница 84: ...6 18 0006081362_200906 TBG 45P 60P TBG 45 60 EN 676...
Страница 85: ...7 18 0006081362_200906 N 0002910950n1 1 2 3 4 5 6 7 1200 8 2 9 10 11 12 EN 676 1 1 5 2 2...
Страница 86: ...8 18 0006081362_200906 3 6 5 4 7 8 8a 9 9...
Страница 91: ...13 18 0006081362_200906 4 5 12 13 CO2 10 O2 3 CO 0 1 14 921 15 16 30 31 3 30 31 17 30 31...
Страница 92: ...14 18 0006081362_200906 0002935680 A B C TBG 45 45P 4 5 4 TBG 60P 4 10 TBG 60 4 11 4 1 2 3 4 5...
Страница 94: ...16 18 0006081362_200906 fig 1 fig 2 fig 4 fig 3 1 2 1 2 3 4 5 2 3 6 7 8 8 3 4 10 9 4 0002935680...
Страница 96: ...18 18 0006081362_200906 1 1 230 2 2 3 3 4 4 5 a 5 6 6 7 7 8 8 9 9 1 1 230 2 2 3 3 4 4 5 5 6 6 1 1 2 2 3 3 4 4...
Страница 98: ...2 18 0006081362_200906 a b c a b c d e f g...
Страница 99: ...3 18 0006081362_200906 2 RC a b c d a b c d e a b a b c d...
Страница 102: ...6 18 0006081362_200906 LPG TBG 45 60 TBG 45P 60P LPG EN267...
Страница 103: ...7 18 0006081362_200906 EN676 1 1 5m 2m 2 1 2 3 4 5 6 7 1200kW 8 9 10 11 12...
Страница 104: ...8 18 0006081362_200906 3 1 2 6 5 7 4 1 8 8A 9 8 9 17...
Страница 105: ...9 18 0006081362_200906 Fig 1 1 2 3 Fig 2 4 5 Fig3 3 6 9 5 10mm 8 5 9mm IP 44 IEC EN60529 5N m 1...
Страница 107: ...11 18 0006081362_200906 LED tw LME21 10 AL 10 AL 1 3...
Страница 109: ...13 18 0006081362_200906 15 16 30 31 30 31 17 30 31...
Страница 110: ...14 18 0006081362_200906 A B C TBG 45 45P 4 5 4 TBG 60P 4 10 TBG 60 4 11 4 1 2 3 4 5...
Страница 112: ...16 18 0006081362_200906 1 1 2 Fig 1 2 3 4 5 Fig 2 3 6 7 8 8 Fig 3 4 9 10 Fig 4...
Страница 113: ...17 18 0006081362_200906 1 1 Fig 1 2 4 180 4a Fig 1 2 3 1 3 Fig 2 5 6 7 4 5 6 7 1 i 0 6 TBG 45 60 0002934700...
Страница 114: ...18 18 0006081362_200906 230V 230V 14...
Страница 115: ...115 122 00060811362_200906 3 A RU LGB 21 L1 N...
Страница 116: ...116 122 00060811362_200906 3 A RU LGB 21 L1 N...
Страница 117: ...117 122 00060811362_200906 3 A RU L1 N...
Страница 118: ...118 122 00060811362_200906 3 A RU TR SARI YE L MAV KAHV RE NG S YAH NOLU S YAH KABL0 L1 N...
Страница 121: ......