2
english
BTL PF _ 400- _ _ _ _ -C15A _ _ _ _ -000S35
Magnetostrictive Linear Position Sensor – Profile Style
Installation
NOTICE
Improper installation
Improper installation can compromise the function of the
BTL and result in damage.
►
Ensure that no strong electrical or magnetic fields
are present in the direct vicinity of the BTL.
►
Be sure to maintain the specified distances and
separations.
Dimensions see image.
Captive magnets
BTL5-F-2814-1S
BTL5-F-2814-1S
1
44
50.4
1
31.5
36.5
Note when installing the magnet:
– Avoid lateral forces.
– Connect the magnet to the machine member with a
joint rod (see
Accessories
).
Floating magnets
BTL5-P-3800-2
BTL5-P-5500-2
1
34+4 39+4
B
C
1
45+10 50+10
B
C
BTL6-A-3800-2
BTL6-A-3801-2
1
53+4 58+4
B
C
1
42+4
47+4
B
C
Installation (continued)
Observe the following when installing the magnet:
– To ensure the accuracy of the magnetostrictive linear
position sensor, fasten the magnet to the moving
member of the machine only using non-magnetizable
screws (stainless steel, brass, aluminum).
– The moving member must guide the magnet on a
parallel line to the BTL.
– The distance A between the magnet and parts made of
magnetizable material must be at least 10 mm.
A
A
– For distance B between the magnet and the BTL and
for the center offset C (see image) the following values
must be maintained:
Magnet type
Distance B
1)
Offset C
BTL5-P-3800-2
0.1…4 mm
±2 mm
BTL5-P-5500-2
5…15 mm
±15 mm
BTL6-A-3800-2
4…8 mm
2)
±5 mm
BTL6-A-3801-2
4…8 mm
2)
±5 mm
1) The selected distance must remain constant over the entire measuring
length.
2) For optimal measurement results: 6…8 mm
– When using multiple magnets a minimum separation of
65 mm must be maintained between them.
Any orientation is permitted. Mount the BTL on a level
surface of the machine using the provided mounting
clamps and cylinder-head screws.
In order to avoid resonant frequencies caused by
vibrations, we recommend positioning the
mounting clamps at irregular intervals.