www.balluff.com
15
english
When IO-Link communication is active, the
analog output is disabled.
The minimum selectable measuring range is
5 mm.
6.1
Voltage Output 0…10 V
Fig. 6-1:
10.5 V
Before
After
10 V
0 V
Target position
Range Teach
minimum
Range Teach
maximum
Analog voltage output
For the adjustment process, see section 6.4 on
page 16.
6.2
Current Output 4…20 mA
Fig. 6-2:
Before
After
20 mA
3.5 mA
4 mA
Target position
Range Teach
minimum
Range Teach
maximum
Analog current output
For the adjustment process, see section 6.4 on
page 16.
6
Analog interface and switching output
6.3
Switching output
Switching signal (factory setting)
Fig. 6-3:
active
inactive
Switching signal (factory setting)
Taught-in switching signal
(Teach 1 (switch-on point) and Teach 2 (switch-off point)
carried out)
Fig. 6-4:
active
inactive
Teach 1
Teach 2
Teaching in possible in the complete
configured measuring range
Taught-in switching signal
N.O./N.C.
As standard, the switching output is configured as a
normally open contact (image above). It can be converted
to normally closed logic.
Fig. 6-5:
Teaching in possible in the complete
configured measuring range
active
inactive
Teach 1
Teach 2
Taught-in switching signal
For the adjustment process, see section 6.4 on
BMP 01- EL1PP _ 1A- _ _ _ _ -00 -P _ _ /P _ _ -S4/P _ _ -S75
Magnetic Field Positioning System