www.balluff.com
29
english
8.1
Detection range/measuring range
Measuring range
32, 64, 96, 128, 160,
192, 224, 256 mm
Resolution
IO-Link
Analog
1 µm
12 Bit
Linearity deviation
1)
±250 µm
Repeat accuracy
1)
±100 μm
Temperature drift
(max. from end value)
± 0.3 %
Sampling rate
≤ 1000 Hz
1)
Applies to the measuring range
8.2
Ambient conditions
Ambient temperature
–25 °C…+85 °C
Storage temperature
–25 °C…+85 °C
Contamination scale
3
Shock rating
per EN 60068-2-27
Half-sinus, 30 g, 11 ms
Vibration
per EN 60068-2-6
55 Hz, 1-mm amplitude,
3 × 30 min
Degree of protection as per
IEC 60529
IP67
8.3
Supply voltage (external)
Operating voltage U
B
15…30 V DC
No-load current I
o max.
at U
e
25 mA
Rated insulation voltage U
i
75 V DC
Rated operating voltage U
e
DC
24 V
Readiness delay t
v
≤ 100 ms
Residual ripple (% of U
e
)
≤ 10%
Load resistance R
L
(Analog I)
≤ 500 Ohm
Output current (Analog U)
≤ 5 mA
Load capacity of switching
output
≤ 100 mA
8.4
Electrical connection
Bending radius, fixed routing
≥ 3 × cable diameter
Cable diameter
2.4 mm
Cable length
See
Wire cross-section
0.07 mm
2
Connection
…P_ _-S75
…P_ _-S4
…P_ _
M8×1 connector, 4-pin
M12×1 connector, 4-pin
open cable end
Connection type
Cable with/without
connector
Number of conductors
4
Reverse polarity protection
Yes
Short-circuit resistance
Yes
Cable jacket material
PUR
8.5
Output / interface
Analog output
Analog, voltage (0…10 V)
/ current (4…20 mA)
switchable
Interface
IO-Link 1.1
SIO mode
Yes
8.6
Displays
Function indicator
Green LED
Power indicator
Yellow LED
Error display
Red LED
8.7
Mechanical data
Dimensions
42, 74, 106, 138, 170,
202, 234, 266 × 17.5
× 9.6 mm
Tightening torque
0.1 Nm
Housing material
PA12, aluminum
8
Technical data
BMP 01- EL1PP _ 1A- _ _ _ _ -00 -P _ _ /P _ _ -S4/P _ _ -S75
Magnetic Field Positioning System
Содержание BMP 01-EL1PP 1A Series
Страница 2: ...www balluff com...