12
english
4
Installation and connection (continued)
4.3
Mounting with floating target
For mounting with a floating target, mounting screws are
required (see accessories on page 30).
Distances and tolerances to be observed
To guarantee function, the following distances for the
target must be observed:
Fig. 4-11:
12±2
5.8
0±4
Target
BMP
Distances and tolerances, shown using an example of a
round magnet target Ø10×10 mm with remanence B
R
~360 mT
Hole spacing
Hole spacing = Measuring range + 2 mm (hole pattern
tolerance = ±0.05 mm)
Example: Measuring range 128 mm
Hole spacing = 130 mm ±0.05 mm
Direct and inverse mounting
The BMP can be mounted directly (sensing surface
pointing to mounting surface) or inversely.
Fig. 4-12:
N
S
Installation with floating target (inverse mounting), axially
polarized target (example, N and S can also be swapped)
For inverse mounting, a recess for the button
and the LEDs must be provided (for dimensions,
see Fig. 4-13); otherwise, the BMP can only be
configured via IO-Link.
Fig. 4-13:
1
6
5
.3
9
.1
17.8
1.4
6.9
3
2.7
Ø 8
R 1.5
Dimensions and distances of the button and LEDs
1.
Provide boreholes (distances depend on type; see
on
page 12).
2.
Attach the BMP to a surface using mounting screws
on page 30) and a torque of
0.1 Nm.
BMP 01-EL1PP _ 1A- _ _ _ _ -00 -P _ _ /P _ _ -S4/P _ _ -S75
Magnetic Field Positioning System
Содержание BMP 01-EL1PP 1A Series