7-2 Specifications
MN1957
www.baldormotion.com
7.1.4 Digital inputs
7.1.5 Digital outputs - general purpose
7.1.6 Relay output
Description
Unit
Value
Type
Opto-isolated
USR V+ supply voltage
Nominal
Minimum
Maximum
VDC
24
12
30
Input voltage
Active
Inactive
VDC
> 12V
< 2V
Input current
Maximum per input, USR V+ = 24 V
mA
7
Description
Unit
Value
USR V+ supply voltage
Nominal
Minimum
Maximum
VDC
24
12
30
Output current
Max. source per output, one output on
Max. source per output, all outputs on
Maximum total output current
mA
DOUT0-7
DOUT8-11
350
350
62.5
125
500
500
Update interval
(Mint)
Immediate
Switching time
No load on output
With 7 mA or greater load
100 ms
10
μ
s
Description
Unit
Value
Contact rating
(resistive)
1 A @ 24 VDC
or
0.25 A @ 30 VAC
Operating time
(max)
ms
5
Servo Systems Co. • 115 Main Road • P.O. Box 97 • Montville, NJ,
07045-0097 • (973) 335-1007 • Toll Free: (800) 922-1103
Fax: (973) 335-1661 • www.servosystems.com