Operation 5-11
www.baldormotion.com
5.4.3 Setting the drive enable output
The drive enable output allows NextMove ESB-2 to disable the drive in the event of an error.
Each axis can be configured with its own drive enable output, or can share an output with
other axes. If an output is shared, an error on any of the axes sharing the output will cause all
of them to be disabled.
The drive enable output can either be a digital output or the relay.
1. In the Toolbox, click the Digital I/O icon.
2. At the bottom of the Digital I/O screen, click the
Digital Outputs
tab.
The left of the screen shows two yellow icons,
High and Low. These describe how the output
should behave when activated (to enable the
axis).
3. If you are going to use the relay, ignore this
step and go straight to step 4.
If you are going to use a digital output, drag
the appropriate yellow icon to the grey OUT
icon that will be used as the drive enable
output. Its color will change to bright blue.
4. If you are going to use the
relay, drag the Relay0 icon
to the grey Drive Enable
OP icon on the right of the
screen.
To configure multiple axes to use the error output, repeat this step for the other axes.