5-30 Operation
MN1957
www.baldormotion.com
5.10 Digital input/output configuration
The Digital I/O window can be used to setup other digital inputs and outputs.
5.10.1 Digital input configuration
The Digital Inputs tab allows you to define how each digital input will be triggered, and if it
should be assigned to a special purpose function such as a Home or Limit input. In the
following example, digital input 1 will be set to trigger on an active low input, and allocated to
the forward limit input of axis 0:
1. In the Toolbox, click the Digital I/O icon.
2. At the bottom of the Digital I/O screen, click
the
Digital Inputs
tab.
The left of the screen shows a column of
yellow icons - High, Low, Rising, Falling
and Rise/Fall. These describe how the
input will be triggered.
3. Drag the
Low
icon
onto the
IN1
icon
. This will setup
IN1
to respond to a low input.
Servo Systems Co. • 115 Main Road • P.O. Box 97 • Montville, NJ,
07045-0097 • (973) 335-1007 • Toll Free: (800) 922-1103
Fax: (973) 335-1661 • www.servosystems.com