www.baldormotion.com
3-36 Basic Installation
MN1901
3.9.9 Preventing a program running at startup / restoring communciation
If switches 5 and 9 are set to On and switch 8 is set to Off, any program already in the
MintDrive
II
that contains an Auto command will be prevented from running automatically at
startup.
It is possible for normal (Baldor Binary Protocol) serial communication to be lost if bit 5 of the
Mint keyword
COMMSMODE
has been set. This can occur when alternative communication
protocols have been used. This DIP switch procedure will clear bit 5, restoring normal serial
communication.
On
5
Reapply power. Mint program
with Auto command will not run.
1.
2.
On
9
3.
Off
8
Remove
power.
Figure 23 - Preventing the Auto command from running a stored Mint program, or restoring
normal serial communication