www.baldormotion.com
4-12 Input / Output
MN1901
4.3.4 Digital outputs - X3
Location
Connector X3
Pin Name
Mint keyword
18 DOUT0
OUTX.0
19 DOUT1
OUTX.1
20 DOUT2
OUTX.2
Description
Three general-purpose optically isolated digital outputs.
Output current: 50mA maximum each output
Update intervals:
Immediate: Software (Mint programs)
LOOPTIME
(default 1ms):
DRIVEENABLEOUTPUT
,
DRIVEOKOUTPUT
and
GLOBALERROROUTPUT
functions.
Outputs controlled by functions
MOVEOUT
,
MOVEOUTX
,
MOVEPULSEOUTX
,
PULSEOUTX
.
Programmable: PLC Task functions
Each optically isolated PNP output is designed to source current from the USR V+ supply as
shown in Figure 35. The maximum saturated voltage across any of the outputs when active is
1.0VDC, so they can be used as TTL compatible outputs. If the outputs are used to directly
drive a relay, a suitably rated flyback diode must be fitted across the relay coil, observing the
correct polarity. This is to protect the output from the back-EMF generated by the relay coil
when it is de-energized. The outputs can be controlled directly using the Mint keyword
OUTX
(for example
OUTX.2=1
). The sense of the outputs can be configured in Mint WorkBench, and
their states are displayed in the Spy window.
OUTX.
x
MintDrive
II
NEC PS2562L-1
Load
(Relay with
flyback diode
shown)
USR V+
DOUT0
6
18
‘X3’
CGND
8
Figure 35 - X3 digital output circuit - DOUT0 shown
18
20
CGND 8
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com