background image

■ 

PARAMAX SINGLE STAGE DRIVES SPA Series should be handled, installed and 

 

maintained by trained technicians. Carefully read the maintenance manual before use.        

■ 

Oil is removed from PARAMAX SINGLE STAGE DRIVES SPA Series before shipment.

 

Supply oil according to the maintenance manual before operation.

■ 

A copy of this maintenance manual should be sent to the actual user of PARAMAX

 

SINGLE STAGE DRIVES SPA Series.

■ 

This maintenance manual should be maintained by the user.

PARAMAX  DRIVE

Single Stage Drives 

SPA

 Series 

 Maintenance Manual

GM2003E

-1

Содержание PARAMAX SPA Series

Страница 1: ...ed from PARAMAX SINGLE STAGE DRIVES SPA Series before shipment Supply oil according to the maintenance manual before operation A copy of this maintenance manual should be sent to the actual user of PA...

Страница 2: ...nings regarding safety and proper use DANGER CAUTION The unit should be operated only within its design and performance specifications otherwise injury or damage to a system may occur Keep hands and a...

Страница 3: ...eduction ratio Input power Service factor Serial number Fig 1 Rating plate CAUTION Unpack the unit after verifying that it is positioned right side up otherwise injury may result Verify that the unit...

Страница 4: ...or hole is provided be sure to use it After mounting PARAMAX SINGLE STAGE DRIVE SPA Series on a system however do not hoist the entire system using the hanging bolt or hole Otherwise personal injury o...

Страница 5: ...stall PARAMAX SINGLE STAGE DRIVE SPA Series on a sufficiently rigid base Use installation bolts corresponding to JIS strength class 8 8 or its equivalent The torque of installation bolts is shown in t...

Страница 6: ...ion In such case the location and number of grease nipples should be confirmed in advance The bearings are packed with grease at the time of shipment Supply grease according to the input speed every 1...

Страница 7: ...20 ISO VG320 AGMA 6EP ENERGOL GR XP 320 ALPHA SP320 OPTIGEAR BM320 TRIBOL 1100 320 GEAR COMPOUNDS EP320 MEROPA WM320 SPARTAN EP320 MOBIL GEAR 632 OMALA 320 CARTER EP320 ENER GREASE LS EP2 SPHEEROL AP3...

Страница 8: ...tored without flowing water where the air temperature is 0 C or less remove water from its inside If something adheres to the inside of the cooling coil the cooling effect is lowered Check the cooling...

Страница 9: ...wise splashing lubricant may cause burns When reversing the direction of rotation first bring the unit to a complete stop then commence reverse rotation otherwise the system may be damaged Check the o...

Страница 10: ...ng daily inspection take appropriate corrective measures based on 10 Troubleshooting P 10 If normal operation is still not possible contact the nearest agent distributor or service office Inspection i...

Страница 11: ...shop Place the key in position Repair at a specialized workshop Adjust the protective device Change the connection The output shaft turns when there is no load Excessive temperature rise Oil leakage A...

Страница 12: ...herical roller bearing 6002 Spherical roller bearing 6003 Spherical roller bearing 6004 Spherical roller bearing 6502 Oil seal 6504 Oil seal Fig 8 SPA Series 4101 6001 6004 2501 6002 3601 6502 4121 65...

Страница 13: ...God or any other reasons beyond the control of the Seller 8 waste exhaustion normal wear and tear or deterioration on the parts of the Products such as bearing oil seal 9 any other troubles problems...

Страница 14: ......

Отзывы: