www.baldormotion.com
3-12 Basic Installation
MN1901
Note:
Power to single phase models may be derived by connecting two phases of an
appropriate three-phase supply (L1 and L2 for example). When supplying AC
power in this way, the voltage between the two phases must not exceed the rated
input voltage of the MintDrive
II
. A two pole breaker must be used to isolate both
lines. Fuses must be fitted in both lines. Circuit breaker or fuse are not supplied.
For CE compliance, see Appendix D.
Circuit Breaker
Circuit breaker or fuse are not supplied.
For CE Compliance, see Appendix C.
L1
From
supply
Fuses
L2
L3
L1
L2
L3
From
supply
L1
L2
L3
Figure 5 - Circuit breaker and fuse, three-phase (package sizes E, G, H)
Note:
Metal conduit or shielded cable should be used. Connect conduits so the use of a
line reactor or RC device does not interrupt EMI/RFI shielding.
3.4.5 Power supply filters
To comply with EEC directive 89/336/EEC, an AC power filter of the appropriate type must be
connected. This can be supplied by Baldor and will ensure that the MintDrive
II
complies with
the CE specifications for which it has been tested. Table 1 lists the appropriate filters:
MintDrive
II
current
Input voltages
current
rating
115VAC, 1
Φ
230VAC, 1
Φ
230VAC, 3
Φ
230-460VAC, 3
Φ
2.5A
FI0015A00 or FI0029A00
FI0018A00
5A
FI0015A02 or FI0029A00
FI0018A00
7.5A
FI0029A00
FI0018A00
15A
FI0018A01
FI0018A01
20A
FI0018A01
27.5A
FI0018A01
Table 1 - Baldor filter part numbers
All single-phase MintDrive
II
models can be mounted directly onto the body of filter FI0029A00,
reducing the amount of panel area required for filter and drive.