MN715J
Parameter Values B-3
Parameter Values
Level 1 Continued
OUTPUT Block
Continued
Parameter
Adjustable Range
Factory
Setting
User
Setting
ANALOG OUT
Frequency
Freq Command
AC Current
AC Voltage
Bus Voltage
Control Temp
Process Feedback
Set Point Command
Zero CAL
100% CAL
Frequency
ANALOG SCALE
10-160%
100%
KEYPAD SETUP Block
Parameter
Adjustable Range
Factory
Setting
User
Setting
KEYPAD STOP KEY
Remote ON, Remote OFF
Remote ON
KEYPAD STOP MODE
Regen Braking
Coast-No Regen
Regen Braking
KEYPAD RUN FWD
OFF, ON
ON
KEYPAD RUN REV
OFF, ON
ON
KEYPAD JOG FWD
OFF, ON
ON
KEYPAD JOG REV
OFF, ON
ON
SWITCH ON FLY
OFF, ON
OFF
LOC. HOT START
OFF, ON
OFF
V/HZ AND BOOST Block
Parameter
Adjustable Range
Factory
Setting
User
Setting
CTRL BASE FREQUENCY
50.00-120.00Hz
60.00Hz
TORQUE BOOST
00.0 - 15.0%
Factory Set
SLIP COMP ADJ
0.00 - 6.00Hz
0.00Hz
V/HZ PROFILE
0-100%
0%=Linear Profile
0%
3–PT OPERATION
OFF, ON
OFF
3–PT VOLTS
000.0-100.0%
0.0%
3–PT FREQUENCY
000.0-Ctrl Base Freq.
(150Hz max)
0.00Hz
MAX OUTPUT VOLTS
0-460 (for 460 volt units)
0-230 (for 230 volt units)
0-230 (for 115 volt units)
Factory Set
Содержание ID15J101-ER
Страница 1: ...Series 15J Inverter Control 7 04 MN715J Installation and Operating Manual ...
Страница 5: ...iv Table of Contents MN715J ...
Страница 11: ...2 4 General Information MN715J ...
Страница 59: ...4 22 Programming and Operation MN715J ...
Страница 75: ...6 6 Specifications and Product Data MN715J ...
Страница 79: ...A 4 Dynamic Brake Hardware MN715J ...
Страница 86: ...Appendix C Remote Keypad Mounting Template MN715J Remote Keypad Mounting Template C 1 ...