4-10 Programming and Operation
MN715J
Reset Parameters to Factory Settings
Sometimes it is necessary to restore the parameter values to the factory
settings (after new software is installed, etc.). This procedure describes how
to restore factory settings.
Note: All parameter values already programmed will be changed when resetting the
control to factory settings.
Action
Description
Display
Apply Power
If no faults and programmed for
LOCAL operation.
Press PROG key
Enter program mode.
Press
Y
or
B
key
Scroll to Level 2 Blocks.
Press ENTER key
Select Level 2 Blocks.
Press
Y
or
B
key
Scroll to the Miscellaneous block.
Press ENTER key
Select Miscellaneous block.
Press ENTER key
Access Factory Settings
parameter.
Press
Y
key
Scroll to YES, to choose original
factory settings.
Press ENTER key
Restores factory settings.
Press RESET key
Return to Miscellaneous block.
Press
Y
key
Scroll to menu exit.