TROUBLESHOOTING
Relieve the pressure
prior
to checking or repairing the
meter. Make sure all valves,
controls and pumps are
operating correctly.
Symptom
Possible Cause
Remedy
Battery Icon is displayed Batteries are low
Replace batteries
Display Blank
Meter asleep
Loose battery connection
Batteries Dead
Push reset button
Remove battery pack and
check battery connection/
Push reset button
Replace batteries/Push
reset button
Meter does not latch for
batching
Meter not in AUTO mode
Meter not reset after prior batch
Low batteries
Press AUTO button and pro-
gram batch size
Press RESET button
Check for battery icon/
replace batteries/push
RESET button
Slow or no fluid flow
Filter is clogged
Pump pressure is low
Foreign material is jamming
meter
Clean or replace the filter in
the swivel nut
Turn up the pump pressure
Contact your local distributor
for repair
Meter inaccurate
Scale factor not correct for fluid
Enter program mode, check
and reset program factor
Batch overruns program
value
Pulse delay value set too low
Enter program mode, reset
pulse delay to higher value
21