Error Codes
The meter has several Error Codes that may be displayed. These provide indication, at the
meter, that there is an error in communication between the meter and keypad.
F01
The meter has received an invalid response from the keypad.
• To clear the error, press the Reset button on the meter.
• Press the Reset button a second time to retry communications with the keypad.
F02
The meter has not received a response from the keypad during communications.
• To clear the error code, press the Reset button on the meter.
• To retry communications with the keypad, press the Reset button a second time.
• There may be an obstruction blocking the RF signal between the meter and keypad.
It may be necessary to change your physical location.
F04
There is a damaged cable assembly within the meter.
• This meter should be taken out of service.
• This meter may be used reliably in EPM Mode.
• RF Mode will exhibit erratic behavior.
SF0 (Scale Factor 0)
The Scale Factor setting for the meter is set to 0.000.
• To input a valid Scale Factor for the meter follow the instructions in the Change Factory
Settings section of this manual.
All other Error Codes
are for factory purposes only.
• To clear the meter, press Reset.
6
Содержание 3331-018
Страница 22: ...ITEM PART DESCRIPTION 1 Battery Holder Assembly 2 Bottom Case with Screws 18...
Страница 23: ...1 2 3 ITEM PART DESCRIPTION 1 Rubber Boot 2 Display Assembly 3 RF Register Assembly Not Shown Swivel NPT 19...
Страница 24: ...1 2 3 ITEM PART DESCRIPTION 1 Valve Assembly 2 Gear Service Kit with O ring 3 Trigger Assembly 20...